An Analysis of the Application of a Medical Imaging Artificial Intelligence System for a Spontaneous Fluorescence Imaging Recognition System Using Pre-Clinical Diabetic Retinopathy as an Example
1 The Third Affiliated Hospital of Wenzhou Medical University, Wenzhou 325100, China
2 Biomedical Engineering, Wenzhou Medical University, Wenzhou 325035, China
Objective: To analyze the application of a medical imaging artificial intelligence system for spontaneous fluorescence imaging recognition using pre-clinical diabetic retinopathy as an example so as to provide a technical exploration for early diagnosis and treatment. Methods: The fundus autofluorescence images of 102 patients (200 eyes) in a control group and 105 patients (200 eyes) in a study group were collected from August 2017 to May 2018. All patients were examined by a slit lamp microscope, preview lens, naked eye or corrected visual acuity and fundus autofluorescence images. The images from the control and study groups were used for analysis. The medical image extraction and recognition system is based on a two-dimensional lattice complexity measurement and was used to analyze the discernible differences between the fundus autofluorescence image of pre-clinical diabetic retinopathy and the normal retinal autofluorescence image. Results: Twenty-five features with comparative significance were extracted. The single and multiple features were tested by 10-fold and 5-fold cross tests for 25 features, and the accuracy rate was 82.47%. Conclusions: Complex analysis of a medical imaging artificial intelligence system can be used to identify the spontaneous fluorescence changes on the fundus of pre-clinical diabetic retinopathy with high accuracy.
徐晓茹1 陈嘉玮1 张元勋1 冯义侠1 柯大观2. 以临床前期糖尿病视网膜病变为例分析医学图像人工智能系统在自发荧光图像识别中的应用[J]. 中华眼视光学与视觉科学杂志, 2019, 21(5): 356-361.
Xiaoru Xu1 Jiawei Chen1 Yuanxun Zhang1Yixia Feng1 Daguan Ke2. An Analysis of the Application of a Medical Imaging Artificial Intelligence System for a Spontaneous Fluorescence Imaging Recognition System Using Pre-Clinical Diabetic Retinopathy as an Example. Chinese Journal of Optometry Ophthalmology and Visual science, 2019, 21(5): 356-361. DOI: 10.3760/cma.j.issn.1674-845X.2019.05.007
Frampton GK, Kalita N, Payne L, et al. Fundus autofluorescence imaging: systematic review of test accuracy for the diagnosis and monitoring of retinal conditions. Eye (Lond), 2017, 31(7): 995-1007. DOI: 10.1038/eye.2017.19.
[2]
Katz G, Levkovitch-Verbin H, Treister G, et al. Mesopic foveal contrast sensitivity is impaired in diabetic patients without retinopathy. Graefes Arch Clin Exp Ophthalmol, 2010, 248(12): 1699-1703. DOI: 10.1007/s00417-010-1413-y.
[3]
von Rtickmann A, Fitzke FW, Bird AC. Distribution of funduaautofluorescence with a scanning Iaser ophthalmoscope. Br JOphthalmol, 1995, 79: 407-412.
[4]
Hajeb Mohammad Alipour S, Rabbani H, Akhlaghi MR. Diabetic retinopathy grading by digital curvelet transform. Comput Math Methods Med, 2012, 2012: 761901. DOI: 10.
11
55/2012/761901.
[5]
Ozmert E, Batio?lu F. Fundus autofluorescence before and after photodynamic therapy for chronic central serous chorioretinopathy. Ophthalmologica, 2009, 223(4): 263-268.
DOI: 10.1159/000210386.
[6]
Saleh MG, Campbell JP, Yang P, et al. Ultra-Wide-Field Fundus Autofluorescence and Spectral-Domain Optical Coherence Tomography Findings in Syphilitic Outer Retinitis. Ophthalmic Surg Lasers Imaging Retina, 2017, 48(3): 208-215. DOI: 10. 3928/23258160-20170301-03.