Objective To compare the difference and accuracy of the two methods of calculation for the Q-value of corneal anterior surface that with tangential radius or sagittal radius. Methods Twenty-four aspheric test objects were manufactured with the Moore diamond turning lathe in this self-controlled study. The test objects were all verified by the TalySurf roughness profiler and the asphericity (Q) and vertex radius of curvature (r0) were fitted. Then, they were examined with the Orbscan Ⅱ corneal topography. The results were applied paired t-test and Bland-Altman figure to perform statistical analysis. Results ①The average r0-values of the horizontal semi-meridian calculated by the sagittal radius and the tangential radius were 7.72±0.09 mm, 7.73±0.09 mm. Both of them were close to but have statistical differences with the fitted value 7.70±0.08 mm. ②There was no statistical differences between Q-values of the horizontal semi-meridian calculated by the sagittal radius and the tangential radius and fitted value (sagittal refractive map: t=1.61, P>0.05; tangent refractive map: t=-0.87, P>0.05). ③The average differences between the Q-values of the horizontal semi-meridian calculated by the tangential radius and fetted values was more close to 0 than sagittal ones, and the 95% consistency limits of upper and lower range was smaller than sagittal ones. Conclusion Although the Q-values of corneal anterior surface calculated by tangential radius and sagittal radius are both reliable, the former is more accurate and stable.
顾春燕,夏哲人,陈如,应靖璐,郑穗联,施明光. 两种角膜前表面Q值计算方法的实验研究[J]. 中华眼视光学与视觉科学杂志, 2016, 18(5): 285-288.
Gu Chunyan*,Xia Zheren,Chen Ru,Ying Jinglu,Zheng Suilian,Shi Mingguang. The experimental research of two methods of calculation for the Q-value of corneal anterior surface. Chinese Journal of Optometry Ophthalmology and Visual science, 2016, 18(5): 285-288. DOI: DOI:10.3760/cma.j.issn.1674-845X.2016.05.007
Roberts C. Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface[J]. J Refract Corneal Surg,1994,10(2):103-111.
[2]
Roberts C. Analysis of the inherent error of the TMS-1 Topographic Modelling System in mapping a radially aspheric surface[J]. Cornea,1995,14(3):258-265.
[3]
Chan JS, Mandell RB, Burger DS, et al. Accuracy of videokeratography for instantaneous radius in keratoconus[J]. Optom Vis Sci,1995,72(11):793-799. DOI:10.1097/00006324-199511000-00004.
[4]
Gatinel D, Haouat M, Hoang-Xuan T. A review of mathematical descriptors of corneal asphericity[J]. J Fr Ophtalmol,2002,25(1):81-90. PMID:11965125.
[5]
Haouat M, Gatinel D, Duong MH, et al. Corneal asphericity in myopes[J]. J Fr Ophtalmol,2002,25(5):488-492.
[6]
Davis WR, Raasch TW, Mitchell GL, et al. Corneal asphericity and apical curvature in children: a cross-sectional and longitudinal evaluation[J]. Invest Ophthalmol Vis Sci,2005,46(6):1899-1906.
[7]
Read SA, Collins MJ, Carney LG, et al. The Topography of the Central and Peripheral Cornea[J]. Invest Ophthalmol Vis Sci,2006,47(4):1404-1415. DOI:10.1167/iovs.05-1181.
[8]
Nieto-Bona A, Lorente-Velázquez A, Mòntes-Micó R. Relationship between anterior corneal asphericity and refractive variables[J]. Graefes Arch Clin Exp Ophthalmol,2009,247(6):815-820. DOI:10.1007/s00417-008-1013-2.
[9]
Zhang Z, Wang J, Niu W, et al. Corneal asphericity and its related factors in 1052 Chinese subjects[J]. Optom Vis Sci,2011, 88(10):1232-1239. DOI:10.1097/OPX.0b013e31822717ca.
Ying J, Wang B, Shi M. Anterior corneal asphericity calculated by the tangential radius of curvature[J]. J Biomed Opt,2012,17(7):075005. DOI:10.1117/1.JBO.17.7.075005.