Comparison of vault measurements by Pentacam and anterior segment OCT after Collamer lens implantation |
Dong Jing,Gao Xiaowei,Hu Yukun,Li Wenjing,Guo Yunlin,Cai Yan,Cao Liping,Liu Liping,Li Xiaohong |
Department of Ophthalmology, No. 474 Hospital of Chinese PLA, Urumqi 830011, China |
|
|
Abstract Objective To compare vault and other biometric measurements obtained after Collamer lens (PPC-ICL) implantation using a Pentacam anterior segment system and an anterior segment optical coherence tomography system (AS-OCT). Methods In this cross-sectional study, vault and other biometric were was measured in 100 eyes of 50 patients after Collamer lens (PPC-ICL) implantation using a Pentacam and AS-OCT. The statisitical significance of the difference between the measurements was evaluated by a paired t-test and consistency was assessed by Bland-Altman analysis. Results The mean vault measured by Pentacam and AS-OCT was 353.8±124.0 µm and 536.2±150.8 µm (t=27.92, P<0.05) with a significant positive relationship (r=0.905, P<0.05). There was a 95% level of consistent interval for the difference in interval width (54.3-310.5 µm). Conclusion The measurements obtaind by Pentacam was much lower than AS-OCT. The difference between the measurements of the vault obtained by the two instruments should be considered and accurately evaluated.
|
Received: 09 March 2016
|
Corresponding Authors:
Gao Xiaowei, Email: gxwgaoxw@263.net
|
|
|
|
[1] |
Alfonso JF, Baamonde B, Fernández-Vega L, et al. Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up[J]. J Cataract Refract Surg,2011,37(5):873-880. DOI:10.1016/j.jcrs.2010.11.040.
|
[2] |
Pesando PM, Ghiringhello MP, Di MG, et al. Posterior chamber phakic intraocular lens (ICL) for hyperopia: ten-year follow-up[J]. J Cataract Refract Surg,2007,33(9):1579-1584. DOI:10.1016/j.jcrs.2007.05.030.
|
[3] |
Ieong A, Hau SC, Rubin GS, et al. Quality of life in high myopia before and after implantable Collamer lens implantation[J]. Ophthalmology,2010,117(12):2295-2300. DOI:10.1016/j.ophtha.2010.03.055.
|
[4] |
Gomez-Bastar A, Jaimes M, Graue-Hernández EO, et al. Long-term refractive outcomes of posterior chamber phakic (spheric and toric implantable collamer lens) intraocular lens implantation[J]. Int Ophthalmol,2014,34(3):583-590. DOI:10.1007/s10792-013-9860-1.
|
[5] |
Choi KH, Chung SE, Chung TY, et al. Ultrasound biomicroscopy for determining visian implantable contact lens length in phakic IOL implantation[J]. J Refract Surg,2007,23(4):362-367.
|
[6] |
Gonvers M, Bornet C, Othenin-Girard P. Implantable contact lens for moderate to high myopia: relationship of vaulting to cataract formation[J]. J Cataract Refract Surg,2003,29(5):918-924.
|
[7] |
Baikoff G, Lutun E, Ferraz C, et al. Analysis of the eye′s anterior segment with optical coherence tomography. Static and dynamic study[J]. Fr Ophthalmol,2005,28(4):343-352.
|
[8] |
Petternel V, K?觟ppl CM, Dejaco-Ruhswurm I, et al. Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye[J]. Ophthalmology,2004,111(2):325-331. DOI:10.1016/j.ophtha.2003.05.013.
|
[9] |
Lindland A, Heger H, Kugelberg M, et al. Changes in vaulting of myopic and toric implantable collamer lenses in different lighting conditions[J]. Acta Ophthalmol,2012,90(8):788-791. DOI: 10.1111/j.1755-3768.2011.02224.x.
|
[10] |
林华优,黄锦海,黎远光,等. 散瞳对Lenstar测量白内障患者眼球生物结构参数及IOL度数计算的影响[J]. 中华眼视光学与视觉科学杂志,2014,16(5):301-305. DOI:10.3760/cma.j.issn.1674-845X.2014.05.010.
|
[11] |
余克明,罗汇慧,庄菁,等. 有晶状体眼后房型人工晶状体植入术后患者在不同瞳孔状态下的眼前段变化[J]. 中华眼视光学与视觉科学杂志,2012,14(6):357-359. DOI:10.3760/cma.j.issn.1674-845X.2012.06.009.
|
[12] |
于莉,黎明,彭云,等. ICL-晶状体间距和虹膜张力对ICL术后并发白内障影响研究[J]. 中国实用眼科杂志,2013,31(6):684-687. DOI:10.3760/cma.j.issn.1006-4443.2013.06.009.
|
[13] |
Du C, Wang J, Wang X, et al. Ultrasound biomicroscopy of anterior segment accommodative changes with posterior chamber phakic intraocular lens in high myopia[J]. Ophthalmology,2012, 119(1):99-105. DOI:10.1016/j.ophtha.2011.07.001.
|
[14] |
Piha SJ, Halonen JP. Infrared pupillometry in the assessment of autonomic function[J]. Diabetes Res Clin Pract,1994,26(1):61-66.
|
|
|
|