Role of Video Terminal Protective Lenses in Relieving Asthenopia of Video
Operators |
Haiming Xu, Jie Yu, Hailan Zhao |
Department of Ophthalmology, People's Hospital of Hangzhou Medical College, Zhejiang Provincial People's Hospital, Hangzhou 310014, China |
|
|
Abstract Objective: To evaluate the effects of video terminal protective lenses in relieving asthenopia of videooperators. Methods: This prospective clinical research included 60 video operators (age range: 26-45years) with asthenopia symptoms while working in the ultrasound department of our hospital. The subjectswere randomly assigned to two groups. The test group (n=30) wore video terminal protective lenses.The control group (n=30) wore ordinary aspherical lenses. After one hour of video operation, binocular vision-related testing and tear break up time (BUT) were measured in all subjects wearing the ordinary aspherical lenses, and an asthenopia questionnaire assessment was administered. After that, subjects in each group underwent contrast sensitivity (CS), and then they worked as usual, wearing their assigned lenses. Three months later, the subjects in each group underwent binocular vision-related testing, and BUT measurements. The asthenopia questionnaire assessment was again administered as well as the adverse reaction questionnaire. Data were analyzed by t-tests and chi-square tests. Results: After wearing videoterminal protective lenses, the CS with glare at low and medium-frequency grating (1.0 cpd, 1.7 cpd, 2.6 cpd) in the test group were significantly higher than in the control group under bright conditions (t=2.181,2.012, 2.088, all P<0.05). Under dark conditions, the CS of various frequencies in the test group also higher than in the control group (t=2.220, 2.558, both P<0.05) at low-frequency grating (1.0 cpd、1.7 cpd). The CS at low-frequency grating in the absence of glare in the test group was higher than in the control group
(bright: t=2.123, 2.530, both P<0.05; dark: t=2.433, 2.140, both P<0.05). In the test group, after wearing the video terminal protective lenses for three months, the amplitude of accommodation, accommodative sensitivity, and BUT were significantly elevated (t=-2.735, -3.281, -2.249, all P<0.05), while the near
point of convergence, near lateral exophoria, and the asthenopia gratings were significantly decreased (t=3.049, 1.369, 3.754, all P<0.05). However, in the control group, the amplitude of accommodation, near point of convergence, accommodative sensitivity, phorias, and BUT after 3 months were not significantly
altered compared with those before the experiment. Further, the asthenopia grating was not significantly decreased. Accommodative converse/Accommodation ratio in neither group was significantly altered compared with before the experiment. At 3 months, the constituent ratio of adverse reactions was not significantly different between the two groups. Conclusions: A 3-month follow-up revealed that compared with ordinary glasses, video terminal protective lenses increased the low- and medium-frequency CS under bright and dark conditions and improved binocular visual function and BUT. The improvements effectively relieved asthenopia and had no severe adverse reactions, suggesting the potential for clinical application.
|
Received: 07 April 2017
|
Fund:This study was funded by Projects of Medical and Health Technology Development
Program in Zhejiang Province (2011KYA020) |
Corresponding Authors:
Hailan Zhao, Department of Ophthalmology, Affiliated Hospital of Hangzhou
Medical College, Zhejiang Provincial People's Hospital, Hangzhou 310014, China (Email: zhaohl333@
vip.sina.com)
|
|
|
|
[1] |
李品浩, 杨文秀, 陈琴, 等. AG490抑制DOCI-LY8和Raji细胞生长及与STAT3信号的关系. 贵阳医学院学报, 2016, 41(2): 130-134, 138.
|
[2] |
朱岩, 汪军. 注视视频终端对泪膜及眼表的影响.国际眼科杂志, 2009, 9(3): 579-580. DOI: 10.3969/j.issn.1672-5123.2009.03.057.
|
[3] |
江臻颖, 瞿小妹, 黎晓新, 等. 七叶洋地黄双苷滴眼液治疗屈光性视疲劳有效性和安全性的临床研究. 中华眼科杂志, 2010, 46(12): 1099-1103. DOI: 10.3760/cma.j.issn.0412-4081.2010.12.012.
|
[4] |
刘祖国, 虞东芳, 林跃生, 等. 润洁萘扑维滴眼液治疗视疲劳的初步临床观察. 眼视光学杂志, 2005, 7(1): 27 -29. DOCI: 10.3760/cma.j.issn.1674-845X.2005.01.009.
|
[5] |
Schmoll C, Khan A, Aspinall P, et al. New light for old eyes:omparing melanopsin-mediated non-visual benefits of blue-light and UV-blocking intraocular lenses. Br J Ophthalmol, 2014, 98(1): 124-128. DOI: 10.1136/bjophthalmol-2013-304024.
|
[6] |
瞿佳主编.视光学理论和方法. 1版. 北京:人民卫生出版社. 2004: 26-57.
|
[7] |
Ustinaviciene R, Obelenis V, Ereminas D. Occupational health problems in modern work environment. Medicina (Kaunas), 2004, 40(9): 897-904.
|
[8] |
Collins MJ, Buehren T, Bece A, et al. Corneal optics after reading, microscopy and computer work. Acta Ophthalmol Scand, 2006, 84(2): 216-224. DOI: 10.1111/j.1600-0420.2005.00547.x.
|
[9] |
瞿小妹, 褚仁远, 汪琳, 等. 注视视频终端对视觉功能的影响.中华眼科杂志, 2005, 41(11): 986-989. DOI: 10.3760/j:issn: 0412-4081.2005.11.007.
|
[10] |
Yap M. The effect of a yellow filter on contrast sensitivity. Ophthalmic Physiol Opt, 1984, 4(3): 227-232.
|
[11] |
Yuan Z, Reinach P, Yuan J. Contrast sensitivity and color vision with a yellow intraocular len. Am J Ophthalmol, 2004, 138(1): 138-140. DOI: 10.1016/j.ajo.2004.02.024.
|
[12] |
Niwa K, Yoshino Y, Okuyama F, et al. Effects of tinted intraocular lens on contrast sensitivity. Ophthalmic Physiol Opt, 1996, 16(4): 297-302.
|
[13] |
van den Berg TJ. Light scattering by donor lenses as a function of depth and wavelength. Invest Ophthalmol Vis Sci, 1997, 38(7): 1321-1332.
|
[14] |
Kinney JA, Schlichting CL, Neri DF, et al. Reaction time to spatial frequencies using yellow and luminance-matched neutral goggles. Am J Optom Physiol Opt, 1983, 60(2): 132-138.
|
[15] |
Neumaier-Ammerer B, Felke S, Hagen S, et al. Comparison of visual performance with blue light-filtering and ultraviolet light-filtering intraocular lenses. J Cataract Refract Surg, 2010, 36(12): 2073-2079. DOI: 10.1016/j.jcrs.2010.06.069.
|
[16] |
Bol'shakova VA. Functional disorders of vision and their prophylaxis in professionals using PC. Med Tr Prom Ekol, 2004, (10):27-30.
|
[17] |
Gur S, Ron S, Heicklen-Klein A. Objective evaluation of visual fatigue in VDU workers. Occup Med (Lond), 1994, 44(4): 201-204.
|
[18] |
王柏敏, 余敏斌, 李劲嵘, 等. 使用计算机终端及不同休息方案对调节聚散功能影响分析. 中国实用眼科杂志, 2010, 28(4): 351-355. DOI: 10.3760/cma.j.issn.1006-4443.2010.04.013.
|
[19] |
Wilkins AJ, Evans BJ, Brown JA, et al. Double-masked placebo-controlled trial of precision spectral filters in children who use coloured overlays. Ophthalmic Physiol Opt, 1994, 14(4): 365-370.
|
[20] |
RayNJ,FowlerS,SteinJF.YellowfiltersCallimprovemagnocellular
|
|
function: motion sensitivity, convergence, accommodation, and reading. Ann N Y Aead Sci, 2005, 1039(1): 283-293.
|
[21] |
Miyake-Kashima M, Dogru M, Nojima T, et al. The effect of antireflection film use on blink rate and asthenopic symptoms during visual display terminal work. Cornea, 2005, 24(5): 567-570.
|
[22] |
Augustin AJ. The physiology of scotopic vision, contrast vision, color vision, and circadian rhythmicity: can these parameters be influenced by blue-light-filter lenses? Retina, 2008, 28(9): 1179-1187. DOI: 10.1097/IAE.0b013e3181835885.
|
|
|
|