An Assessment of Overnight Orthokeratology on tear Film with Different Diagnostic Devices |
Jun Xu,Yuanyuan Lu,Hongna Wang,Xiaomei Wan,Xiangying Ding,Ziyan Yu |
Department of Ophthalmology, The Fourth Affiliated Hospital of the China Medical University, and the Eye Hospital of the China Medical University, Provincial Key Laboratory of Lens Research, Shenyang 110005, China |
|
|
Abstract Objective: To investigate the changes due to wearing long-term overnight orthokeratology lenses on the stability of tear film as measured by different diagnostic devices. Methods: This was a prospective clinical study. One hundred eighteen patients, who were treated with orthokeratology lenses at The Fourth Affiliated Hospital of the China Medical University from January 2016 to October 2017, were included in the study. The patients’ ages ranged from 8 to 18 years (11.8±2.5). Measurements of tear meniscus height (TMH), noninvasive first breakup time [NIBUT (f )] and noninvasive average breakup time [NIBUT (av)] in each subject were obtained with a Keratograph 5M. Measurements were taken before lens wear and 1, 3, and 6 months after lens wear. The lipid layer interference patterns of the lacrimal film were divided by the DR-1 Tearscope Plus. Data were analyzed by repeated measures analysis of variance and by Pearson correlation analysis. Results: 1. Tear meniscus height: The TMH results showed a consistent but not statistically significant difference before and after wearing orthokeratology lenses. 2. NIBUT(f) and NIBUT(av): NIBUT had decreased by the time of the l-month visit (P<0.001); after that, all of the above changes decreased slightly and then stabilized. 3. Grades of tear film quality. There was a decrease in the stability of tear film from before lens wear to 1 month after lens wear (P<0.001), but there were no significant grade differences at 3 months and 6 months compared to prior measurements. 4. There was a small correlation between the variation in the lacrimal film lipid layer interference patterns and the BUT measured by different diagnostic devices during the follow-up study (r=-0.145, P=0.011; r= 0.147,P=0.019). Conclusions: Wearing contact lenses does not induce tear deficiency. It can result in decreasing the stability of tear film during the early stages of lens wear, but stability is gradually restored after that. Oculus keratography and DR-1 Tearscope Plus can assist in the diagnosis of dry eye diseases at different levels.
|
Received: 06 September 2018
|
Fund: Shenyang science and technology project (18-014-4-46); National Natural Science Foundation of China (81703185) |
Corresponding Authors:
Jun Xu, Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, and the Eye Hospital of China Medical University, Provincial Key Laboratory of Lens Research,Shenyang 110005, China (Email: xujunone@126.com)
|
|
|
|
[1] |
瞿小妹, 储仁远. 角膜塑型术临床疗效及其相关因素. 眼视光学杂志, 2004, 6(1): 6-9.
|
[2] |
Cho P, Cheung SW. Retardation of myopia in Orthokeratology (ROMIO) study: a 2-year randomized clinical trial. Invest Ophthalmol Vis Sci, 2012, 53(11): 7077-7085. DOI: 10.1167/
|
|
iovs.12-10565.
|
[3] |
Hiraoka T, Kakita T, Okamoto F, et al. Long-term effect of overnight orthokeratology on axial length elongation in childhood myopia: a 5-year follow-up study. Invest Ophthalmol
|
|
Vis Sci, 2012, 53(7): 3913-3919. DOI: 10.1167/iovs.11-8453.
|
[4] |
Yokoi N, Takehisa Y, Kinoshita S. Correlation of tear lipid layer interference patterns with the diagnosis and severity of dry eye.Am J Ophthalmol, 1996, 122(6): 818-824.
|
[5] |
Sridharan R, Swarbrick H. Corneal response to short-term orthokeratology lens wear. Optom Vis Sci, 2003, 80(3): 200-206.
|
[6] |
刘湘萍, 邓叶华, 雷小浪. 角膜塑形镜夜间佩戴对泪膜影响的临床观察. 中南医学科学杂志, 2016, 44(3): 348-349, 355. DOI:10.15972/j.cnki.43-1509/r.2016.03.030.
|
[7] |
李健, 董平, 王承昕, 等. 夜戴型角膜塑形镜对角膜形态及泪液的影响. 国际眼科杂志, 2015, 15(2): 205-207. DOI: 10.3980/j.issn.1672-5123.2015.2.05.
|
|
|
|