Research Progress on Intraocular Pressure Measurements and Influencing Factors after Corneal Refractive Surgery |
Ce Shi, Likun Xia |
Shengjing Hospital of China Medical University, Shenyang 110004, China |
|
|
Abstract After corneal refractive surgery, the measurement of intraocular pressure is underestimated because central corneal thickness and corneal biomechanical properties are changed during the operation. Accurately evaluating intraocular pressure after corneal refractive surgery has an important clinical significance. The evaluation of postoperative intraocular pressure measurements should take tonometer, central corneal thickness, corneal hysteresis and corneal resistance factors into consideration. This article reviews the intraocular pressure measurements and influencing factors after corneal refractive surgery.
|
Received: 22 November 2018
|
Corresponding Authors:
Likun Xia, Department of Ophthalmology, Shengjing Hospital of China Medical University, Shenyang 110004, China (Email: xialk@sj-hospital.org)
|
|
|
|
[1] |
葛坚, 王宁利. 眼科学. 北京: 人民卫生出版社, 2015: 109-110.
|
[2] |
Chansue E, Tanehsakdi M,Swasdibutra S, et al. Efficacy, predictability and safety of small incision lenticule extraction(SMILE). Eye Vis (Lond), 2015, 2: 14. DOI: 10.1186/s40662-
|
01 |
5-0024-4.
|
[3] |
Li Y, Shi J, Duan X, et al. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol, 2010, 248(12): 1765-1770. DOI: 10.1007/s00417-009-1243-y.
|
[4] |
Wangsupadilok B, Horatanaruang O. The impact of central corneal thickness on intraocular pressure measured by noncontact onometry. J Med Assoc Thai, 2011, 94(5): 574-578.
|
[5] |
张扬, 赵家良, 卞爱玲, 等. 中央角膜厚度、角膜曲率对Goldmann压平眼压计和非接触眼压计测量结果的影响. 中华眼科杂志, 2009, 45(8): 713-718. DOI: 10.3760/cma.j.issn.0412-4081.2009.08.010.
|
[6] |
Lee M, Ahn J. Effects of central corneal stromal thickness and epithelial thickness on intraocular pressure using goldmann applanation and non-contact tonometers. PLoS One, 2016,11(3): e0151868. DOI: 10.1371/journal.pone.0151868.
|
[7] |
Schallhorn JM, Schallhorn SC, Ou Y. Factors that influence intraocular pressure changes after myopic and hyperopic LASIK and photorefractive keratectomy: A large population study.Ophthalmology, 2015, 122(3): 471-479. DOI: 10.1016/j.ophtha.2014.09.033.
|
[8] |
Jethani J, Dave P, Jethani M, et al. The applicability of correction factor for corneal thickness on non-contact tonometer measured intraocular pressure in LASIK treated eyes. Saudi J
|
|
Ophthalmol, 2016, 30(1): 25-28. DOI: 10.1016/j.sjopt.2015.11.001.
|
[9] |
Wei W, Fan Z, Wang L, et al. Correlation analysis between central corneal thickness and intraocular pressure in juveniles in Northern China: The Jinan city eye study. PLoS One, 2014, 9(8):e104842. DOI: 10.1371/journal.pone.0104842.
|
[10] |
Cacho I, Sanchez-Naves J, Batres L, et al. Comparison of intraocular pressure before and after laser in situ keratomileusis refractive surgery measured with perkins tonometry, noncontact tonometry, and transpalpebral tonometry. J Ophthalmol, 2015,2015: 683895. DOI: 10.1155/2015/683895.
|
[11] |
Elsheikh A, Joda A, Abass A, David Garway-Heath.Assessment of the ocular response analyzer as an instrument for measurement of intraocular pressure and corneal
|
|
biomechanics. Curr Eye Res, 2015, 40(11): 1111-1119. DOI:10.3109/02713683.2014.978479.
|
[12] |
李从谊, 段宣初. ORA眼反应分析仪的临床应用价值. 国际眼科杂志, 2009, 9(5): 934-937. DOI:10.3969/j.issn.1672-5123.2009.05.041.
|
[13] |
Yildiz A, Yasar T. Comparison of Goldmann applanation, noncontact,dynamic contour and tonopen tonometry measurements in healthy and glaucomatous eyes, and effect of central corneal thickness on the measurement results. Med Glas (Zenica), 2018,15(2): 152-157. DOI: 10.17392/960-18.
|
[14] |
Özcura F, Y?ld?r?m N, Tambova E, et al. Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus. J Optom, 2017, 10(2): 117-122. DOI:10.1016/j.optom.2016.04.005.
|
[15] |
刘艳丽. 动态轮廓眼压计临床研究进展. 中华眼外伤职业眼病杂志, 2013, 35(11): 878-880. DOI: 10.3760/cma.j.issn.2095-1477.2013.11.032.
|
[16] |
Yilmaz I, Altan C, Aygit ED, et al. Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL. Clin Ophthalmol, 2014, 8: 1069-1074. DOI: 10.2147/OPTH.S63915.
|
[17] |
Güler M, Bilak ?, Bilgin B, et al. Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects. J Glaucoma, 2015,24(8): 613-618. DOI: 10.1097/IJG.0000000000000132.
|
[18] |
李红锋, 欧阳君, 屈晓勇. Goldmann 眼压计与非接触眼压计测量青光眼患者眼压的对比分析. 国际眼科杂志, 2015,15(1): 144-145. DOI: 10.3980/j.issn.1672-5123.2015.1.43.
|
[19] |
Uzbek AK, Kamburo?lu G, Mahmoud AM, et al. Change in biomechanical parameters after flap creation using the Intralase femtosecond laser and subsequent excimer laser ablation. Curr Eye Res, 2011, 36(7): 614-619. DOI: 10.3109/02713683.2010.546952.
|
[20] |
栾春生, 陈晓明, 邓应平, 等. 兔眼中央角膜厚度与Perkins压平眼压关系的研究. 中华眼科杂志, 2005, 41(7): 642-646.DOI: 10.3760/j:issn:0412-4081.2005.07.015.
|
[21] |
吴小影, 刘双珍, 黄佩刚, 等. 准分子激光屈光性角膜切削术后眼压测量值的变化. 中华眼科杂志, 2002, 38(10): 603-605.DOI: 10.3760/j:issn:0412-4081.2002.10.007.
|
[22] |
张潇, 李莹. 近视及散光眼LASIK后非接触眼压计测量值的影响因素及其预测. 中国实用眼科杂志, 2008, 26(9): 930-934.DOI: 10.3760/cma.j.issn.1006-4443.2008.09.016.
|
[23] |
Cheng AC, Fan D, Tang E, et al. Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopc LASIK surgery.Cornea, 2006, 25(1): 26-28.
|
[24] |
Kohlhaas M, Spoerl E, Boehm AG, et al. A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg, 2006, 22(3): 263-267.
|
[25] |
Zare M, Feizi S, Azimzadeh A, et al. Effect of photorefractive keratectomy with mitomycin-C on corneal biomechanical features. Curr Eye Res, 2012, 37(6): 457-462. DOI: 10.3109/
|
02 |
713683.2012.660594.
|
[26] |
Kamiya K,Shimizu K, Ohmoto F. Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in situ keratomileusis. Cornea, 2009,28(7): 765-769. DOI:10.1097/ICO.0b013e3181967082.
|
[27] |
Santhiago MR, Giacomin NT, Smadja D, et al. Ectasia risk factors in refractive surgery. Clin Ophthalmol, 2016, 10: 713-720. DOI: 10.2147/OPTH.S51313.
|
[28] |
Roberts CJ. Importance of accurately assessing biomechanics of the cornea. Curr Opin Ophthalmol, 2016, 27(4): 285-291. DOI:10.1097/ICU.0000000000000282.
|
[29] |
李华, 王雁, 窦瑞, 等. 飞秒激光小切口角膜基质透镜取出术后眼压测量及其影响因素分析. 中华眼科杂志, 2016, 52(1):22-29. DOI: 10.3760/cma.j.issn.0412-4081.2016.01.008.
|
[30] |
史策, 夏丽坤, 刘鹤南, 等. SMILE术后眼压测量值变化及预测. 中华眼视光学与视觉科学杂志, 2018, 20(1): 53-57. DOI:10.3760/cma.j.issn.1674-845X.2018.01.010.
|
[31] |
Shin J, Kim TW, Park SJ, et al. Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and Goldmann applanation tonometry. J Glaucoma, 2015, 24(3):195-201. DOI: 10.1097/IJG.0b013e31829da1ec.
|
[32] |
Wei S, Wang Y, Wu D, et al. Ultrastructural changes and corneal wound healing after SMILE and PRK procedures. Curr Eye Res, 2016, 41(10): 1316-1325. DOI:10.3109/02713683.2015.1114653.
|
[33] |
Xia L, Zhang J, Wu J, et al. Comparison of corneal biological healing after femtosecond LASIK and small incision lenticule extraction procedure. Curr Eye Res, 2016, 41(9): 1202-1208.DOI: 10.3109/02713683.2015.1107590.
|
[34] |
Sachdev G, Sachdev MS, Sachdev R, et al. Unilateral corneal ectasia following small-incision lenticule extraction.J Cataract Refract Surg, 2015, 41(9): 2014-2018. DOI: 10.1016/j.jcrs.2015.08.006.
|
[35] |
Li H, Wang Y, Dou R, et al. Intraocular pressure changes and relationship with corneal biomechanics after SMILE and FSLASIK. Invest Ophthalmol Vis Sci, 2016, 57(10): 4180-4186. DOI: 10.1167/iovs.16-19615.
|
[36] |
Chen M, Yu M, Dai J. Comparison of biomechanical effects of small incision lenticule extraction and laser-assisted subepithelial keratomileusis. Acta Ophthalmol, 2016, 94(7): e586-e591. DOI:10.1111/aos.13035.
|
[37] |
Dou R, Wang Y, Xu L, et al. Comparison of corneal biomechanical characteristics after surface ablation refractive surgery and novel lamellar refractive surgery. Cornea, 2015,
|
34 |
(11): 1441-1446. DOI: 10.1097/ICO.0000000000000556.
|
[38] |
Mastropasqua L, Calienno R, Lanzini M, et al. Evaluation of corneal biomechanical properties modification after small incision lenticule extraction using Scheimpflug-based
|
|
noncontact tonometer. Biomed Res Int, 2014, 2014: 290619. DOI: 10.1155/2014/290619.
|
[39] |
Reinstein DZ, Archer TJ, Randleman JB. Mathematical model to compare the relative tensile strength of the cornea after PRK,LASIK,and small incision lenticule extraction. J Refract Surg,2013, 29(7): 454-460. DOI: 10.3928/1081597X-20130617-03.
|
[40] |
Fel A, Aslangul E, Le Jeunne C. Eye and corticosteroid's use.Presse Med, 2012, 41(4): 414-421. DOI: 10.1016/j.lpm.2012.02.001.
|
[41] |
白继. 角膜屈光手术医师应注意抗炎类滴眼液对术后角膜生物力学的影响. 中华实验眼科杂志, 2012, 30(12): 1057-1059.DOI: 10.3760/cma.j.issn.2095-0160.2012.12.001.
|
[42] |
余敏斌, 高景春, 叶天才, 等. 糖皮质激素性青光眼112 例临床分析. 中华眼科杂志, 2001, 37(5): 346-349. DOI: 10.3760/j:issn:0412-4081.2001.05.008.
|
[43] |
叶天才. 重视对糖皮质激素性青光眼的防治. 中华眼科杂志,2001, 37(6): 401-403. DOI: 10.3760/j:issn:0412-4081.2001.06.001.
|
[44] |
姚乃成, 张虹.激素性青光眼的研究进展. 临床眼科杂志,2007, 15(5): 470-473. DOI: 10.3969/j.issn.1006-8422.2007.05.038.
|
[45] |
律鹏, 张文芳, 鲁建华, 等. 三种抗炎药物在Nd: YAG激光后囊膜切开术后应用的随机对照研究. 中华实验眼科杂志, 2012,30(10): 932-935. DOI: 10.3760/cma.j.issn.2095-0160.2012.10.
|
|
018.
|
[46] |
张钰, 陈跃国, 夏英杰. LASEK术后应用0.5%氯替泼诺滴眼液短程疗法与0.1%氟米龙滴眼液长程疗法的临床效果比较.中华实验眼科杂志, 2015, 33(7): 646-649. DOI: 10.3760/cma.
|
|
j.issn.2095-0160.2015.07.016.
|
[47] |
毛伟, 陆斌, 张哲, 等. 三种糖皮质激素滴眼液预防LASIK术后弥漫性层间角膜炎短期效果比较. 眼科, 2012, 21(5): 336-339.
|
[48] |
Sheppard JD, Comstock TL, Cavet ME. Impact of the topical ophthalmic corticosteroid loteprednol etabonate on intraocular pressure. Adv Ther, 2016, 33(4): 532-552. DOI: 10.1007/s12325-016-0315-8.
|
[49] |
Chaurasia SS, Luengo Gimeno F, Tan K, et al. In vivo real-time intraocular pressure variations during LASIK flap creation. Invest Ophthalmol Vis Sci, 2010, 51(9): 4641-4645. DOI: 10.1167/iovs.10-5228.
|
[50] |
Cheng W, Liu L, Yu S, et al. Real-time intraocular pressure measurements in the vitreous chamber of rabbit eyes during small incision lenticule extraction (SMILE). Curr Eye Res, 2018,43(10): 1260-1266. DOI: 10.1080/02713683.2018.1485949.
|
|
|
|