Comparison of the Stability of Two-Haptic and Four-Haptic Intraocular Lenses in Highly Myopic Eyes |
Yu Du, Wenwen He, Yi Lu, Xiangjia Zhu |
Department of Ophthalmology, Eye & ENT Hospital of Fudan University; Key Laboratory of Myopia of National Health Commission of the People's Republic of China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai 200031, China |
|
|
Abstract Objective: To compare the stability of two-haptic and four-haptic intraocular lenses (IOL) in high myopic eyes. Methods: In this retrospective case-control study, 148 high myopic patients who received uneventful phacoemulsification with the implantation of a two-haptic IOL (Tecnis ZCB00, AMO) or four-haptic IOL (MC X11 ASP, HumanOptics) during October 2016 to June 2017 at the Eye & ENT Hospital of Fudan University were selected. Of these, 54 were in the two-haptic IOL group, and 94 in the four-haptic IOL group. Follow-up was planned for six months after surgery, including routine postoperative examinations. An OPD-Scan III aberrometer was used to evaluate the decentration and tilt of the IOL, higher-order aberrations, and modulation transfer function. Comparisons of IOL decentration and tilt, and visual qualities were conducted between the two groups. An independent-sample t-test, Mann-Whitney U-test, χ2 test, and Spearman correlation test were used in statistical analyses. Results: No statistically significant difference in terms of age, gender, or best-corrected visual acuity was seen between the two groups. However, significant differences were seen between the decentration of the two-haptic IOL group and the four-haptic IOL group when they were divided into subgroups of axial lengths between 26 mm and <28 mm, and between 28 mm and <30 mm [0.26(0.15, 0.33)mm vs. 0.18(0.10, 0.24)mm, Z=-2.81, P=0.005; (0.42±0.28)mm vs. (0.18±0.07)mm, t=2.96, P=0.01]. Meanwhile, significant correlations were found between decentration and axial length in both the two-haptic IOL group (r=0.304, P=0.027) and four-haptic IOL group (r=0.366, P<0.001). Under conditions of a pupil size of 7 mm, better ocular and intraocular higher-order aberrations and coma were seen in the four-haptic IOL group (all P<0.05). Conclusions: For high myopic eyes, the four-haptic IOL seems to be better than the two-haptic IOL in terms of long-term IOL stability and visual quality, especially in low-light conditions.
|
Received: 15 November 2019
|
Fund:National Natural Science Foundation of China (81670835) |
Corresponding Authors:
Xiangjia Zhu, Department of Ophthalmology, Eye & ENT Hospital of Fudan University, Key Laboratory of Myopia of National Health Commission of the People's Republic of China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai 200031, China (Email: zhuxiangjia1982@126. com)
|
|
|
|
[1] |
董彦会, 刘慧彬, 王政和, 等. 中国2005-2014年7~18岁汉族儿童青少年近视现状和增长速度趋势分析. 中华流行病学杂志, 2017, 38(5): 583-587. DOI: 10.3760/cma.j.issn.0254-6450. 2017.05.005.
|
[2] |
周佳, 马迎华, 马军, 等. 中国6省市中小学生近视流行现状及其影响因素分析. 中华流行病学杂志, 2016, 37(1): 29-34. DOI: 10.3760/cma.j.issn.0254-6450.2016.01.006.
|
[3] |
Younan C, Mitchell P, Cumming RG, et al. Myopia and incident cataract and cataract surgery: the blue mountains eye study. Invest Ophthalmol Vis Sci, 2002, 43(12): 3625-3632.
|
[4] |
Giers BC, Khoramnia R, Weber LF, et al. Rotation and decentration of an undersized plate-haptic trifocal toric intraocular lens in an eye with moderate myopia. J Cataract Refract Surg, 2016, 42(3): 489-493. DOI: 10.1016/j.jcrs.2016.02.001.
|
[5] |
Zhu X, He W, Zhang Y, et al. Inferior decentration of multifocal intraocular lenses in myopic eyes. Am J Ophthalmol, 2018, 188: 1-8. DOI: 10.1016/j.ajo.2018.01.007.
|
[6] |
Eppig T, Scholz K, L?ffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye. J Cataract Refract Surg, 2009, 35(6): 1091-1100. DOI: 10.1016/j.jcrs.2009.01.034.
|
[7] |
Zhu X, Zhang Y, He W, et al. Tilt, Decentration, and internal higher-order aberrations of sutured posterior-chamber intraocular lenses in patients with open globe injuries. J Ophthalmol, 2017, 2017: 3517461. DOI: 10.1155/2017/3517461.
|
[8] |
Baumeister M, Bühren J, Kohnen T. Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations. J Cataract Refract Surg, 2009, 35(6): 1006-1012. DOI: 10.1016/j.jcrs.2009.01.023.
|
[9] |
Nagy ZZ, Kránitz K, Takacs AI, et al. Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies. J Refract Surg, 2011, 27(8): 564-569. DOI: 10.3928/1081597X-20110607-01.
|
[10] |
王敏, 王于蓝, 宋超, 等. 三种非球面人工晶状体在高度近视眼囊袋内偏中心和倾斜的比较. 眼科新进展, 2016, 36(2): 158-161. DOI: 10.13389/j.cnki.rao.2016.0043.
|
[11] |
邢晓杰, 汤欣, 宋慧. ZCB00非球面人工晶状体眼内稳定性及视觉质量观察. 中国实用眼科杂志, 2011, 29(10): 1034-1037. DOI: 10.3760/cma.j.issn.1006-4443.2011.10.011.
|
[12] |
Hayashi K, Harada M, Hayashi H, et al. Decentration and tilt of polymethyl methacrylate, silicone, and acrylic soft intraocular lenses. Ophthalmology, 1997, 104(5): 793-798. DOI: 10.1016/ s0161-6420(97)30231-0.
|
[13] |
Hayashi K, Hayashi H, Nakao F, et al. Comparison of decentration and tilt between one-piece and three-piece polymethyl methacrylate intraocular lenses. Br J Ophthalmol, 1998, 82(4): 419-422. DOI: 10.1136/bjo.82.4.419.
|
[14] |
Holden BA, Fricke TR, Wilson DA, et al. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology, 2016, 123(5): 1036-1042. DOI: 10.1016/ j.ophtha.2016.01.006.
|
[15] |
Xu L, Li Y, Wang S, et al. Characteristics of highly myopic eyes: the Beijing Eye Study. Ophthalmology, 2007, 114(1): 121-126. DOI: 10.1016/j.ophtha.2006.05.071.
|
[16] |
Wu LJ, You QS, Duan JL, et al. Prevalence and associated factors of myopia in high-school students in Beijing. PLoS One, 2015, 10(3): e0120764. DOI: 10.1371/journal.pone.0120764.
|
[17] |
Zhu XJ, Zhou P, Zhang KK, et al. Epigenetic regulation of αAcrystallin in high myopia-induced dark nuclear cataract. PLoS One, 2013, 8(12): e81900. DOI: 10.1371/journal.pone.0081900.
|
[18] |
邢晓杰, 汤欣, 宋慧, 等. 四种非球面人工晶状体植入术后倾斜和偏心的比较. 中华眼科杂志, 2010, 46(4): 332-336. DOI: 10.3760/cma.j.issn.0412-4081.2010.04.011.
|
[19] |
Chantra S, Pachimkul P, Naripthaphan P. Wavefront and ocular spherical aberration after implantation of different types of aspheric intraocular lenses based on corneal spherical aberration. J Med Assoc Thai, 2011, 94 Suppl 2: S71-75.
|
[20] |
Hayashi K, Hayashi H. Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg, 2005, 31(2): 337-342. DOI: 10.1016/ j.jcrs.2004.06.042.
|
[21] |
Korynta J, Bok J, Cendelin J. Changes in refraction induced by change in intraocular lens position. J Refract Corneal Surg, 1994, 10(5): 556-564.
|
[22] |
张瑞智, 宋慧, 汤欣. 不同设计一片式非球面人工晶状体术后倾斜与偏心比较及视觉质量研究. 中国实用眼科杂志, 2014, 32(4): 419-423. DOI: 10.3760/cma.j.issn.1006-4443.2014.04. 007.
|
[23] |
宁远. 不同类型非球面IOL植入术后稳定性及慧差变化的对比研究. 沈阳: 中国医科大学, 2012.
|
[24] |
Ma S, Zheng D, Lin L, et al. Comparison of Visual quality after implantation of big bag and akreos adapt intraocular lenses in patients with high myopia. Eye Sci, 2015, 30(1): 18-22.
|
[25] |
张斌, 刘丹岩, 柴茜楠, 等. 偏心和旋转对非球面Toric人工晶状体成像质量影响的实验研究. 中华眼视光学与视觉科学杂志, 2018, 20(1): 19-25. DOI: 10.3760/cma.j.issn.1674- 845X.2018.01.004.
|
[26] |
王首雁, 刘澍, 陈国民, 等. 超声乳化白内障吸除联合改良式囊袋张力环植入治疗悬韧带异常白内障. 中华眼视光学与视觉科学杂志, 2011, 13(6): 463-465. DOI: 10.3760/cma. j.issn.1674-845X.2011.06.016.
|
|
|
|