|
|
Advances in Rotationally Asymmetric Multifocal Intraocular Lenses |
Xiaomin Liu, Yusen Huang |
State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University Shandong Academy of Medical Sciences, Qingdao 266071, China |
|
|
Guide |
|
Abstract With the continuous development of intraocular lens design technology and the continuous improvement of quality of life for a new generation of aging population, cataract phacoemulsification combined with intraocular lens implantation can achieve better overall vision and higher visual quality. This is the common expectation of the cataract surgeon and the patient. Rotationally asymmetric multifocal intraocular lenses (MIOLs) reduce the incidence of adverse optical phenomena while providing distance, intermediate and near vision, meeting the needs of patients' lives and work. In this paper, the design, clinical effects and research progress of in vitro experiments on rotationally asymmetric MIOLs are reviewed.
|
Received: 11 July 2019
|
|
Fund: National Natural Science Foundation (81670839, 81970788); Natural Science Foundation of Shandong Province (ZR2019PH060); Shandong Provincial Key Research and Development Program (2018CXGC1205) |
Corresponding Authors:
Yusen Huang, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University Shandong Academy of Medical Sciences, Qingdao 266071, China (Email: huang_yusen@126.com)
|
|
|
|
[1] |
Alió JL, Plaza-Puche AB, Javaloy J, et al. Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design. J Refract Surg, 2013, 29(4): 252-259. DOI: 10.3928/1081597X-20130318- 04.
|
[2] |
Venter JA, Barclay D, Pelouskova M, et al. Initial experience with a new refractive rotationally asymmetric multifocal intraocular lens. J Refract Surg, 2014, 30(11): 770-776. DOI: 10.3928/1081597X-20141021-09.
|
[3] |
McNeely RN, Pazo E, Spence A, et al. Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses. J Cataract Refract Surg, 2017, 43(8): 1020-1026. DOI: 10.1016/j.jcrs.2017.05.039.
|
[4] |
Venter JA, Pelouskova M, Collins BM, et al. Visual outcomes and patient satisfaction in 9 366 eyes using a refractive segmented multifocal intraocular lens. J Cataract Refract Surg, 2013, 39(10): 1477-1484. DOI: 10.1016/j.jcrs.2013.03.035.
|
[5] |
Alió JL, Plaza-Puche AB, Javaloy J, et al. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens. Ophthalmology, 2012, 119(3): 555-563. DOI: 10.1016/ j.ophtha.2011.08.036.
|
[6] |
Alió JL, Plaza-Puche AB, Javaloy J, et al. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL. J Refract Surg, 2012, 28(2): 100-105. DOI: 10.3928/1081597X-20120110-01.
|
[7] |
王潇, 陈碧超, 曹丹敏, 等. 旋转非对称折射型多焦点人工晶状体植入术后早期效果. 中华眼视光学与视觉科学杂志, 2019, 21(4): 259-264. DOI: 10.3760/cma.j.issn.1674- 845X.2019.04.004.
|
[8] |
Muñoz G, Albarrán-Diego C, Ferrer-Blasco T, et al. Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens. J Cataract Refract Surg, 2011, 37(11): 2043-2052. DOI: 10.1016/j.jcrs.2011.05.045.
|
[9] |
林志博, 黄芳, 潘安鹏, 等. 区域折射型多焦点人工晶状体植入术后视觉质量的临床研究. 中华眼视光学与视觉科学杂志, 2017, 19(8): 482-487. DOI: 10.3760/cma.j.issn.1674- 845X.2017.08.006.
|
[10] |
Rosa AM, Loureiro Silva MF, Lobo C, et al. Comparison of visual function after bilateral implantation of inferior sector-shaped near-addition and diffractive-refractive multifocal IOLs. J Cataract Refract Surg, 2013, 39(11): 1653-1659. DOI: 10.1016/j.jcrs.2013.05.047.
|
[11] |
Alfonso JF, Fernández-Vega L, Blázquez JI, et al. Visual function comparison of 2 aspheric multifocal intraocular lenses. J Cataract Refract Surg, 2012, 38(2): 242-248. DOI: 10.1016/ j.jcrs.2011.08.034.
|
[12] |
Venter JA, Pelouskova M, Bull CE, et al. Visual outcomes and patient satisfaction with a rotational asymmetric refractive intraocular lens for emmetropic presbyopia. J Cataract Refract Surg, 2015, 41(3): 585-593. DOI: 10.1016/j.jcrs.2014.06.035.
|
[13] |
McNeely RN, Pazo E, Millar Z, et al. Threshold limit of postoperative astigmatism for patient satisfaction after refractive lens exchange and multifocal intraocular lens implantation. J Cataract Refract Surg, 2016, 42(8): 1126-1134. DOI: 10.1016/ j.jcrs.2016.05.007.
|
[14] |
McAlinden C, Moore JE. Multifocal intraocular lens with a surface-embedded near section: Short-term clinical outcomes. J Cataract Refract Surg, 2011, 37(3): 441-445. DOI: 10.1016/ j.jcrs.2010.08.055.
|
[15] |
Song IS, Yoon SY, Kim JY, et al. Influence of near-segment positioning in a rotationally asymmetric multifocal intraocular lens. J Refract Surg, 2016, 32(4): 238-243. DOI: 10.3928/ 1081597X-20160217-06.
|
[16] |
Charman WN, Atchison DA. Decentred optical axes and aberrations along principal visual field meridians. Vis Res, 2009, 49(14): 1869-1876. DOI: 10.1016/j.visres.2009.04.024.
|
[17] |
Alió JL, Piñero DP, Plaza-Puche AB, et al. Visual outcomes and optical performance of a monofocal intraocular lens and a newgeneration multifocal intraocular lens. J Cataract Refract Surg, 2011, 37(2): 241-250. DOI: 10.1016/j.jcrs.2010.08.043.
|
[18] |
Ramón ML, Piñero DP, Pérez-Cambrodí RJ. Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs. J Refract Surg, 2012, 28(2): 93-99. DOI: 10.3928/1081597X-20111213-02.
|
[19] |
de Gracia P, Dorronsoro C, Marcos S. Multiple zone multifocal phase designs. Opt Lett, 2013, 38(18): 3526-3529. DOI: 10.1364/ OL.38.003526.
|
[20] |
Nanavaty MA, Spalton DJ, Marshall J. Effect of intraocular lens asphericity on vertical coma aberration. J Cataract Refract Surg, 2010, 36(2): 215-221. DOI: 10.1016/j.jcrs.2009.08.024.
|
[21] |
Alió JL, Plaza-Puche AB, Piñero DP, et al. Comparative analysis of the clinical outcomes with 2 multifocal intraocular lens models with rotational asymmetry. J Cataract Refract Surg, 2011, 37(9): 1605-1614. DOI: 10.1016/j.jcrs.2011.03.054.
|
[22] |
Alió JL, Plaza-Puche AB, Montalban R, et al. Visual outcomes with a single-optic accommodating intraocular lens and a lowaddition-power rotational asymmetric multifocal intraocular lens. J Cataract Refract Surg, 2012, 38(6): 978-985. DOI: 10.1016/j.jcrs.2011.12.033.
|
[23] |
Bonaque-González S, Ríos S, Amigó A, et al. Influence on visual quality of intraoperative orientation of asymmetric intraocular lenses. J Refract Surg, 2015, 31(10): 651-657. DOI: 10.3928/1081597X-20150922-01.
|
[24] |
de Wit DW, Diaz J, Moore TC, et al. Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision. J Cataract Refract Surg, 2015, 41(5): 945- 955. DOI: 10.1016/j.jcrs.2014.07.045.
|
[25] |
Pazo EE, Richoz O, McNeely R, et al. Optimized visual outcome after asymmetrical multifocal IOL rotation. J Refract Surg, 2016, 32(7): 494-496. DOI: 10.3928/1081597X- 20160503-01.
|
[26] |
McNeely RN, Pazo E, Spence A, et al. Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses. J Cataract Refract Surg, 2016, 42(12): 1721- 1729. DOI: 10.1016/j.jcrs.2016.10.016.
|
[27] |
Woodcock MG, Lehmann R, Cionni RJ, et al. Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month results. J Cataract Refract Surg, 2016, 42(6): 817-825. DOI: 10.1016/j.jcrs.2016.02.048.
|
[28] |
Mandal P, Berrow EJ, Naroo SA, et al. Validity and repeatability of the aladdin ocular biometer. Br J Ophthalmol, 2014, 98(2): 256-258. DOI: 10.1136/bjophthalmol-2013-304002.
|
[29] |
Pazo EE, McNeely RN, Richoz O, et al. Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment. J Cataract Refract Surg, 2017, 43(11): 1420-1429. DOI: 10.1016/j.jcrs.2017.08.013.
|
[30] |
García-Domene MC, Felipe A, Peris-Martínez C, et al. Image quality comparison of two multifocal IOLs: Influence of the pupil. J Refract Surg, 2015, 31(4): 230-235. DOI: 10.3928/ 1081597X-20150319-02.
|
[31] |
Alió JL, Plaza-Puche AB, Piñero DP. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance. J Refract Surg, 2012, 28(4): 253-258. DOI: 10.3928/1081597X-20120314-01.
|
[32] |
van der Linden JW, van Velthoven M, van der Meulen I, et al. Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens. J Cataract Refract Surg, 2012, 38(1): 68-73. DOI: 10.1016/ j.jcrs.2011.06.034.
|
[33] |
Gatinel D, Houbrechts Y. Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench. J Cataract Refract Surg, 2013, 39(7): 1093-1099. DOI: 10.1016/j.jcrs.2013.01.048.
|
[34] |
Montés-Micó R, López-Gil N, Pérez-Vives C, et al. In vitro optical performance of nonrotational symmetric and refractivediffractive aspheric multifocal intraocular lenses: impact of tilt and decentration. J Cataract Refract Surg, 2012, 38(9): 1657- 1663. DOI: 10.1016/j.jcrs.2012.03.040.
|
[35] |
Liu X, Xie L, Huang Y. Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens. J Cataract Refract Surg, 2019, 45(4): 507-514. DOI: 10.1016/j.jcrs.2018.10.045.
|
[36] |
Plaza-Puche AB, Alió JL, MacRae S, et al. Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses. J Refract Surg, 2015, 31(5): 300-307. DOI: 10.3928/1081597X-20150423-03.
|
|
|
|