Evaluation of the Accuracy of the Intraocular Lens Power Calculation Formula after Refractive Surgery Based on Evidence-Based Medicine |
Meng Liu1, Cheng Dai2, Xiaodong Lyu3, Binzhong Li1 |
1School of Basic Medicine, North Sichuan Medical College, Nanchong 637000, China
2Department of Ophthalmology, Af?liated Hospital of North Sichuan Medical College, Nanchong 637000,China
3Department of Clinical Medicine, North Sichuan Medical College, Nanchong 637000, China |
|
|
Guide |
|
Abstract Objective:To evaluate the accuracy of the formula for calculating the power of implanted intraocular lenses in cataract patients with previous refractive correction surgery.Methods:This was an evidence-based medical research study. The Cochrane library, PubMed, CNKI, WanFang and Metstr databases were searched to collect all the studies reporting the accuracy of the intraocular lens calculation formula after refractive surgery. The search time was self-limited to November 2020. ADDIS software was used for data merging and mesh meta-analysis. The recording parameter is the probability that the predictive error rangefor refractive error after cataract surgery was within ±0.50 D and ±1.00 D. Based on ADDIS software, the statistical test is carried out by using the Node-Split Model.Results:A total of 10 studies were included,with 475 cases and 659 eyes. The results of Network meta-analysis showed that for cataract patients with previous myopic refractive surgery correction history, the most accurate formulas within the refractive error range of ±0.50 D and ±1.00 D were the Modify Hoffer Q and OCT formulas. The highest accuracy formulas for a refractive error range within ±0.50 D and ±1.00 D for hyperopic patients were HolladayⅡand Haigis. The Haigis formula was the most accurate for predicting refractive error of the range within±0.50 D and ±1.00 D for patients undergoing radial keratotomy.Conclusions:For cataract patients who have a history of refractive surgery, the calculation and prediction of intraocular lens power must be comprehensively evaluated based on their refractive state and the type of refractive surgery.
|
Received: 30 May 2021
|
|
Fund: he Ministry of Education Research Start-up Fund for Returned Overseas Students [(2010)1174];Nanchong City Science and Technology Strategic Cooperation Project in 2020 (20SXQT0152) |
Corresponding Authors:
Binzhong Li, School of Basic Medicine, North Sichuan Medical College, Nanchong
637000, China (Email: libinzhong@nsmc.edu.cn)
|
|
|
|
[1] |
Harb EN, Wildsoet CF. Origins of refractive errors: Environmental and genetic factors. Annu Rev Vis Sci, 2019, 5(1): 47-72. DOI: 10.1146/annurev-vision-091718-015027.
|
[2] |
Grzybowski A, Kanclerz P, Tsubota K, et al. A review on the epidemiology of myopia in school children worldwide. BMC Ophthalmol, 2020, 20(1): 27. DOI: 10.1186/s12886-019-1220-0.
|
[3] |
Wang W, Ni S, Li X, et al. Femtosecond laser-assisted cataract surgery with implantation of a diffractive trifocal intraocular lens after laser in situ keratomileusis: A case report. BMC Ophthalmol, 2018, 18(1): 160. DOI: 10.1186/s12886-018-0834-y.
|
[4] |
American Academy of Ophthalmology. Radial keratotomy for myopia. Ophthalmology, 1989, 96(5): 671-687. DOI: 10.1016/ S0161-6420(89)32849-1.
|
[5] |
Davis G. The evolution of cataract surgery. Mo Med, 2016, 113(1): 58-62.
|
[6] |
Sanders D, Retzlaff J, Kraff M, et al. Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas. J Am Intraocul Implant Soc, 1981, 7(4): 337-340. DOI: 10.1016/s0146-2776(81)80031-6.
|
[7] |
竺向佳, 孟佳琪, 卢奕. 重视悄然来临的“屈光手术后时代”. 中华眼视光学与视觉科学杂志, 2020, 22(3): 161-165. DOI: 10.3760/cma.j.cn115909-20190811-00224.
|
[8] |
Savini G, Hoffer KJ. Intraocular lens power calculation in eyes with previous corneal refractive surgery. Eye Vis (Lond), 2018, 5: 18. DOI: 10.1186/s40662-018-0110-5.
|
[9] |
刘晓敏, 黄钰森. 无病史资料的角膜屈光术后IOL度数测算方 法的比较. 中华眼视光学与视觉科学杂志, 2017, 19(1): 53-57. DOI: 10.3760/cma.j.issn.1674-845X.2017.01.010.
|
[10] |
Abulafia A, Hill WE, Koch DD, et al. Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg, 2016, 42(3): 363-369. DOI: 10.1016/j.jcrs.2015.11.039.
|
[11] |
Wang L, Tang M, Huang D, et al. Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery. Ophthalmology, 2015, 122(12): 2443-2449. DOI: 10.1016/j.ophtha.2015.08.037.
|
[12] |
杨琳, 吕勇. 试论LASIK术后白内障手术所需人工晶状体的 屈光度计算问题. 中华眼外伤职业眼病杂志, 2017, 39(12): 881-884. DOI: 10.3760/cma.j.issn.2095-1477.2017.12.001.
|
[13] |
朱珂珂, 穆红梅. 放射状角膜切开术后人工晶状体屈光度计 算的临床观察. 国际眼科杂志, 2019, 19(11): 1967-1969. DOI: 10.3980 /j.issn.1672-5123.2019.11.35.
|
[14] |
张景尚, 王进达, 刘雪, 等. LASIK术后白内障患者应用不同 公式计算的人工晶状体植入后效果分析. 眼科新进展, 2016, 36(5): 435-438. DOI: 10.13389 /j.cnki.rao. 2016.0116.
|
[15] |
车辚. Shammas-PL公式预测准分子术后人工晶状体屈光度 的临床观察. 吉林大学, 2016.
|
[16] |
Hamill EB, Wang L, Chopra HK, et al. Intraocular lens power calculations in eyes with previous hyperopic laser in situ keratomileusis or photorefractive keratectomy. J Cataract Refract Surg, 2017, 43(2): 189-194. DOI: 10.1016/j.jcrs.2016.11.041.
|
[17] |
Francone A, Lemanski N, Charles M, et al. Retrospective comparative analysis of intraocular lens calculation formulas after hyperopic refractive surgery. PLoS One, 2019, 14(11): e0224981. DOI: 10.1371/journal.pone.0224981.
|
[18] |
Wang L, Spektor T, de Souza RG, et al. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery. J Cataract Refract Surg, 2019, 45(10): 1416-1421. DOI: 10.1016/j.jcrs.2019.05.020.
|
[19] |
Patel P, Ashena Z, Vasavada V, et al. Comparison of intraocular lens calculation methods after myopic laser-assisted in situkeratomileusis and radial keratotomy without prior refractive data. Br J Ophthalmol, 2020, 104(10): 1-7. DOI: 10.1136/ bjophthalmol-2020-317681.
|
[20] |
Huang D, Tang M, Wang L, et al. Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis). Trans Am Ophthalmol Soc, 2013, 111(9): 34-45.
|
[21] |
Mahdavi S, Holladay J. IOLMaster 500 and integration of the Holladay 2 formula for intraocular lens calculations. Eur Ophthalmic Rev, 2011, 5(2): 134. DOI: 10.17925/EOR.2011. 05.02.134.
|
[22] |
李兴育, 赵云娥, 王勤美. IOL Master测量短眼轴眼人工 晶状体计算公式准确性比较. 中华眼视光学与视觉科学 杂志, 2010, 12(5): 375-377. DOI: 10.3760/cma.j.issn.1674- 845X.2010.05.013.
|
[23] |
魏丽清, 陈榆, 廉恒丽, 等. SRK/T公式与优化Haigis公式在 高度近视眼中的应用比较. 中华眼视光学与视觉科学杂志, 2016, 18(12): 747-750, 756. DOI: 10.3760/cma.j.issn.1674- 845X.2016.12.009.
|
[24] |
Turnbull AM, Crawford GJ, Barrett GD. Methods for intraocular lens power calculation in cataract surgery after radial keratotomy. Ophthalmology, 2020, 127(1): 45-51. DOI: 10.1016/j.ophtha.2019.08.019.
|
[25] |
常晓可, 吴立平, 许荣. 三种无病史资料人工晶状体度数计算 公式在角膜屈光术后白内障手术中的应用比较. 中华眼视光 学与视觉科学杂志, 2021, 23(3): 185-191. DOI: 10.3760/cma. j.cn115909-20200619-00263.
|
[26] |
Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas. Ophthalmology, 2018, 125(2): 169- 178. DOI: 10.1016/j.ophtha.2017.08.027.
|
[27] |
Connell BJ, Kane JX. Comparison of the Kane formula with existing formulas for intraocular lens power selection. BMJ Open Ophthalmol, 2019, 4(1): e000251. DOI: 10.1136/ bmjophth-2018-000251.
|
[28] |
陆勤康, 查桂平, 赖晓明, 等. 角膜屈光手术后人工晶状体度 数的测算. 中华眼视光学与视觉科学杂志, 2015, 17(9): 554- 557. DOI: 10.3760/cma.j.issn.1674-845X.2015.09.009.z
|
|
|
|