The Influence on Wave-Front Aberrations after the Implantation of an Implantable Collamer Lens with CentraFLOW |
Yanhua Liu1, Hao Chen2, Zhongsheng Zhang1, Wenhui Chen1, Hengsong Lu1 |
Jiangxi Province Nanchang Aier Eye Hospital, Nanchang 330000, China 2Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China |
|
|
Guide |
|
Abstract Objective: To investigate the influence of an implantable collamer lens with CentraFLOW (ICL V4c) on total wave-front aberrations, corneal wave-front aberrations and intraocular wave-front aberrations in moderate and high myopia patients after the implantation. Methods: This was a prospective study of 88 eyes of 44 moderate and high myopia patients who received ICL V4c implants in Nanchang Aier Hospital during May 2019 to December 2020. The Corneal refractive analyzer was used to measure total wave-front aberrations, corneal wave-front aberrations and intraocular wave-front aberrations at 3 mm, 4 mm, and 6 mm pupil diameters preoperatively and at 3 months postoperatively. A paired t-test was used to analyze the changes in total, corneal, and intraocular wave-front aberrations from preoperative measurements to measurements at 3 months postoperatively. Measurements included total, Tilt(S1), higherorder, coma, trefoil, and spherical aberrations. Results: At 3 months postoperatively, the safety index and efficacy index of the surgery were 1.15±0.12 and 1.11±0.12, respectively. At 3, 4, and 6 mm pupil diameters, the postoperative total aberrations were 0.34±0.14, 0.57±0.23, and 1.81±0.83 μm, respectively, and total intraocular aberrations were 0.34±0.11, 0.52±0.16, and 1.74±0.68 μm, respectively, which were significantly reduced compared to preoperative aberrations (total aberrations: t=14.67, P<0.001; t=16.68, P<0.001; t=14.35, P<0.001; total intraocular aberrations: t=15.41, P<0.001; t=13.89, P<0.001; t=13.21, P<0.001), At a 6 mm pupil diameter, the postoperative total higher-order aberrations, coma, and spherical aberrations had increased significantly compared to preoperative eyes (t=-3.62, P=0.001; t=-2.84, P=0.008; t=-2.94, P=0.006). The postoperative intraocular higher-order aberrations and coma had significantly increased compared to preoperative eyes (t=-2.65, P=0.013; t=-3.02, P=0.005). Other aberrations did not show significant changes compared to preoperative eyes. Conclusion: ICL V4c implantation is safe and effective for correcting moderate and high myopia. It can reduce total aberrations and total intraocular aberrations, and there is no significant change in corneal aberrations.
|
Received: 17 July 2021
|
|
Fund: |
Corresponding Authors:
Hengsong Lu, Jiangxi Province Nanchang Aier Eye Hospital, Nanchang 330000, China (Email: luhandwu@163.com)
|
|
|
|
[1] |
Biscevic A, Ahmedbegovic-Pjano M, Pasalic A, et al. Changes in the higher order ocular aberrations and central corneal thickness after T-PRK and Fs-LASIK. Acta Inform Med, 2020, 28(2): 98-102. DOI: 10.5455/aim.2020.28.98-102.
|
[2] |
郑燕, 周跃华, 张晶, 等. FS-LASIK、WF-LASIK与SMILE术 后视觉质量比较的研究.中华眼科杂志, 2020, 56(2): 118-125. DOI: 10.3760/cma.j.issn.0412-4081.2020.02.007.
|
[3] |
Kim J, Choi SH, Lim DH, et al. Comparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK. BMC Ophthalmol, 2020, 20(1): 192. DOI: 10.1186/s12886-020-01459-0.
|
[4] |
唐忞, 马代金. 角膜地形图引导的FS-LASIK与常规FS-LASIK 术后视觉质量比较. 中华眼视光学与视觉科学杂志, 2020, 22(6): 427-433. DOI: 10.3760/cma.j.cn115909-20190718-00202
|
[5] |
Huamao M, Xun C, Mi T, et al. Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c). BMC Ophthalmol, 2018, 18(1): 141. DOI: 10.1186/s12886-018-0805-3.
|
[6] |
Kocová H, Vlková E, Michalcová L, et al. Implantation of posterior chamber phakic intraocular lens for myopia and hyperopia-long-term clinical outcomes. J Fr Ophtalmol, 2017, 40(3): 215-223. DOI: 10.1016/j.jfo.2016.10.009.
|
[7] |
Tian Y, Jiang HB, Jiang J, et al. Comparison of implantable collamer lens visian ICL V4 and ICL V4c for high myopia: a cohort study. Medicine (Baltimore), 2017, 96(25): e7294. DOI: 10.1097/MD.0000000000007294.
|
[8] |
申 苑 莎 , 康 刚 劲 , 王 妍 茜 , 等 . 高 度 近 视 I C L V 4 c 植 入 术 后 早 期 客 观 视 觉 质 量 及 视 觉 相 关 生 活 质 量 分 析 . 国际眼科杂志 , 2020, 20(6): 1035-1039. DOI: CNKI:SUN:GJYK.0.2020-06-027.
|
[9] |
刘逾 , 陈海婷 , 牛广增 , 等 . SMILE 与 ICL V4c 植入术 矫 正 高 度 近 视 的 临 床 效 果 及 视 觉 质 量 对 比 分 析 . 河 北医科大学学报, 2021, 42(2): 186-191. DOI: 10.3969/ j.issn.1007-3205.2021.02.014.
|
[10] |
Dilek Y, Ufuk Ü, Alper A, et al. Early results with a new posterior chamber phakic intraocular lens in patients with high myopia. J Ophthalmol, 2018, 2018: 1329874. DOI: 10.1155/2018/1329874.
|
[11] |
Dougherty PJ, Taylor P. Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes. Clin Ophthalmol, 2017, 11: 273-277. DOI: 10.2147/OPTH. S120427.
|
[12] |
陈珣, 王晓瑛, 缪华茂, 等. 新型中央孔型有晶状体眼后房 型人工晶状体(ICL V4c)用于矫正中高度近视眼的临床结 果. 复旦学报(医学版), 2017, 44(1): 34-41. DOI: 10.3969/ j.issn.1672-8467.2017.01.006.
|
[13] |
文佰伟, 兰长骏, 廖萱. 视觉质量评价方法的研究进展. 眼科 新进展, 2017, 37(8): 793-796. 10.13389/j.cnki.rao.2017.0201.
|
[14] |
Shimizu K, Kamiya K, Igarashi A, et al. Intraindividual comparison of visual performance after posterior chamber phakic intraocular lens with and without a central hole implantation for moderate to high myopia. Am J Ophthalmol, 2012, 154(3): 486-494. DOI: 10.1016/j.ajo.2012.04.001.
|
[15] |
徐欢欢, 葛轶睿, 黄振平. 波前像差对视觉质量的影响分 析. 临床眼科杂志, 2020, 28(5): 456-458. DOI: 10.3969/ j.issn.1006-8422.2020.05.018.
|
[16] |
刘玉璞, 李雪冬, 鲁媛媛, 等. 高度近视眼后房型ICL植入术后 波前像差的改变. 国际眼科杂志, 2013, 13(03): 462-465. DOI: 10.3980/j.issn.1672-5123.2013.03.11.
|
[17] |
Wei R, Li M, Zhang H, et al. Comparison of objective and subjective visual quality early after implantable collamer lens V4c (ICL V4c) and small incision lenticule extraction (SMILE) for high myopia correction. Acta Ophthalmol, 2020, 98(8): e943-e950. DOI: 10.1111/aos.14459.
|
[18] |
Al-Mohaimeed MM. Effect of the Optical Zone Ablation Diameter on Higher Order Aberrations After Transepithelial Photorefractive Keratectomy: A Cohort Study. Cureus, 2021, 13(9): e17630. DOI: 10.7759/cureus.17630.
|
[19] |
Sun WK, Yang H, Yoon G, et al. Higher-order aberration changes after implantable collamer lens implantation for myopia. Am J Ophthalmol, 2011, 151(4): 653-662.eI. DOI: 10.1016/j.ajo.2010.10.031.
|
[20] |
Villegas EA, Alcón E, Rubio E, et al. One-year follow-up of changes in refraction and aberrations induced by corneal incision. PLoS One, 2019, 14(11): e0224823. DOI: 10.1371/ journal.pone.0224823.
|
[21] |
赵纪伟, 李美, 付丽, 等. 白内障超声乳化术的角膜切口位置 与术后手术源性角膜高阶像差的相关性研究. 医学临床研究, 2019, 36(9): 1810-1812. DOI:10.3969/j.issn.1671-7171.2019.09.052.
|
|
|
|