Vault is the most important indicator to evaluate the security after phakic posterior chamber intraocular lens implantation. Poor vault or extremely high vault can lead to a series of complications. At present, many studies have suggested that many factors can affect postoperative vault, such as anterior chamber depth, white to white, the crystalline lens thickness, light intensity,accommodation and so on. In this paper, the factors affecting postoperative vault were reviewed, so as to provide help for the evaluation of postoperative security.
戚梦莹,曾庆延. 有晶状体眼后房型人工晶状体植入术后拱高的影响因素研究进展[J]. 中华眼视光学与视觉科学杂志, 2016, 18(12): 765-768.
Qi Mengying*,Zeng Qingyan. The progress of influencing factors of the vault after the phakic posterior chamber intraocular lens implantation . Chinese Journal of Optometry Ophthalmology and Visual science, 2016, 18(12): 765-768. DOI: DOI:10.3760/cma.j.issn.1674-845X.2016.12.014
Alfonso JF, Baamonde B, Fernandez-Vega L, et al. Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up[J]. J Cataract Refract Surg,2011,37(5):873-880. DOI:10.1016/j.jcrs.2010.11.040.
[2]
Chang JS, Meau AY. Visian Collamer phakic intraocular lens in high myopic Asian eyes[J]. J Refract Surg,2007,23(1):17-25.
[3]
Sanders DR, Schneider D, Martin R ,et al. Toric Implantable Collamer Lens for moderate to high myopic astigmatism[J]. Ophthalmology,2007,114(1):54-61.
[4]
Khalifa YM, Goldsmith J, Moshirfar M. Bilateral explantation of Visian Implantable Collamer Lenses secondary to bilateral acute angle closure resulting from a non-pupillary block mechanism[J]. J Refract Surg,2010,26(12):991-994. DOI:10.3928/1081597X-20100521-01.
[5]
Fernandes P, Gonzalez-Meijome JM, Madrid-Costa D, et al. Implantable collamer posterior chamber intraocular lenses: a review of potential complications[J]. J Refract Surg,2011,27(10):765-776. DOI:10.3928/1081597X-20110617-01.
[6]
Alfonso JF, Fernandez-Vega L, Lisa C, et al. Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age[J]. J Cataract Refract Surg,2012,38(1):46-53. DOI:10. 1016/j.jcrs.2011.07.035.
Lim DH, Lee MG, Chung ES, et al. Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth[J]. Am J Ophthalmol,2014,158(3):447-454 e441. DOI:10.1016/j.ajo.2014.06.005.
[10]
Schmidinger G, Lackner B, Pieh S, et al. Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients[J]. Ophthalmology,2010,117(8):1506-1511.
[11]
Alfonso JF, Fernandez-Vega L, Lisa C, et al. Long-term evaluation of the central vault after phakic Collamer(R) lens (ICL) implantation using OCT[J]. Graefes Arch Clin Exp Ophthalmol, 2012,250(12):1807-1812. DOI:10.1007/s00417-012-1957-0.
[12]
Kojima T, Maeda M, Yoshida Y, et al. Posterior chamber phakic implantable collamer lens: changes in vault during 1 year[J]. J Refract Surg,2010,26(5):327-332.
[13]
Zeng QY, Xie XL, Chen Q. Prevention and management of collagen copolymer phakic intraocular lens exchange: causes and surgical techniques[J]. J Cataract Refract Surg,2015,41(3):576-584. DOI:10.1016/j.jcrs.2014.06.036.
[14]
Reinstein DZ, Archer TJ, Silverman RH, et al. Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound[J]. J Refract Surg,2009,25(2):185-194.
[15]
Choi KH, Chung SE, Chung TY, et al. Ultrasound biomicroscopy for determining visian implantable contact lens length in phakic IOL implantation[J]. J Refract Surg,2007,23(4):362-367.
Oh J, Shin HH, Kim JH, et al. Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy[J]. Ophthalmology,2007,114(9):1685-1688.
[18]
Du GP, Huang YF, Wang LQ, et al. Changes in objective vault and effect on vision outcomes after implantable Collamer lens implantation: 1-year follow-up[J]. Eur J Ophthalmol,2012,22(2):153-160. DOI:10.5301/EJO.2011.8359.
[19]
Sanders DR, Vukich JA, Doney K, et al. U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia[J]. Ophthalmology,2003,110(2):255-266.
[20]
Dougherty PJ, Rivera RP, Schneider D, et al. Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy[J]. J Cataract Refract Surg,2011,37(1):13-18. DOI: 10.1016/j.jcrs.2010.07.014.
[21]
Kojima T, Yokoyama S, Ito M, et al. Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy[J]. Am J Ophthalmol,2012,153(4):632-637,637.e1. DOI:10.1016/j.ajo.2011.06.031.
[22]
Baikoff G, Lutun E, Wei J, et al. Anterior chamber optical coherence tomography study of human natural accommodation in a 19-year-old albino[J]. J Cataract Refract Surg,2004,30(3):696-701.
[23]
Petternel V, Koppl CM, Dejaco-Ruhswurm I, et al. Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye[J]. Ophthalmology,2004,111(2):325-331.
[24]
Du C, Wang J, Wang X, et al. Ultrasound biomicroscopy of anterior segment accommodative changes with posterior chamber phakic intraocular lens in high myopia[J]. Ophthalmology,2012, 119(1):99-105.
[25]
Lin H, Yan P, Yu K, et al. Anterior segment variations after posterior chamber phakic intraocular lens implantation in myopic eyes[J]. J Cataract Refract Surg,2013,39(5):730-738. DOI:10.1016/j.jcrs.2012.12.026.
Lindland A, Heger H, Kugelberg M, et al. Changes in vaulting of myopic and toric implantable collamer lenses in different lighting conditions[J]. Acta Ophthalmol,2012,90(8):788-791. DOI: 10.1111/j.1755-3768.2011.02224.x.
Sheng XL, Rong WN, Jia Q, et al. Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism[J]. Int J Ophthalmol,2012,5(4):459-465. DOI:10.3980/j.issn.2222-3959.2012.04.10.
[31]
Lee DH, Choi SH, Chung ES, et al. Correlation between preoperative biometry and posterior chamber phakic Visian Implantable Collamer Lens vaulting[J]. Ophthalmology,2012,119(2):272-277. DOI:10.1016/j.ophtha.2011.07.047.