Objective To evaluate the optical quality of young patients with myopia by using the Double-pass Optical Quality Analysis System (OQASTM II) to establish a new range of reference values; to further provide evidence for the clinical diagnosis and evaluation of myopia in young patients. Methods This was a cross-sectional study. Three hundred forty-two young patients participated in this study. Patients were divided into three groups based on spherical equivalent (SE): a low myopia group, a moderate myopia group, and a high myopia group. Optical quality measurements for a 4.0 mm pupil were performed using the OQASTM II. The following parameters were analyzed: the objective scatter index (OSI), the modulation transfer function cutoff frequency (MTF cutoff), the Strehl ratio (SR), visual acuity (VA) at 100%, 20%, and 9% contrasts and the amplitude of accommodation (AMP). Data were analyzed using ANOVA and pearson correlation. Results ①The normal limits of OSI, MTF cutoff, SR, VA100%, VA20%, VA9%, AMP were 0.48-0.68, 36.54-40.20, 0.22-0.25, 1.22-1.34, 1.25-1.41, 1.32-1.49, 1.18-1.47 in low myopia group, respectively; 0.61-0.76, 34.55-37.07, 0.21-0.22, 1.15-1.24, 1.16-1.26, 1.20-1.30, 1.28-1.48 in moderate myopia, respectively; 1.39-2.20, 28.40-31.99, 0.17-0.19, 0.95-1.07, 0.92-1.05, 0.92-1.05, 1.62-1.88 in high myopia, respectively. As the parameter values increase, visual quality decreases in myopia, while the OSI and AMP values increase. ②The OSI was negatively correlated with the MTF cutoff and SR values and the differences were statistically significant (r=-0.65,-0.50, P<0.05). However, the correlation between age and OSI was not statistically significant (r=0.045, P>0.05). Conclusion This study revealed the normal range of reference values of OQASTM II for patients with different refractive statuses. This could provide evidence for establishing reference values, evaluating the visual quality of patients who have different degrees of myopia and discriminating healthy eyes from eyes that have early abnormalities.
李佳佳,郭秀瑾. 双通道视觉质量分析系统对青年近视患者视觉质量的评估[J]. 中华眼视光学与视觉科学杂志, 2015, 17(5): 292-295.
Li Jiajia,Guo Xiujin. Evaluation of the optical quality of young patients with myopia using the Double-pass Optical Quality Analysis System. Chinese Journal of Optometry Ophthalmology and Visual science, 2015, 17(5): 292-295. DOI: 10.3760/cma.j.issn.1674-845X.2015.05.009
Saad A, Saab M, Gatinel D. Repeatability of measurements with a double-pass system[J]. J Cataract Refract Surg,2010,36(1):28-33.
[4]
Benito A, Perez GM, Mirabet S, et al. Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes[J]. J Cataract Refract Surg,2011,37(8):1481-1487.
[5]
Artal P, Benito A, Perez GM, et al. An objective scatter index based on double-pass retinal images of a point source to classify cataracts[J]. PLoS One,2011,6(2):E16823.
[6]
Cuell JL, Pujol J, Arjona M, et al. Optical quality analysis system: instrument for objective clinical evaluation of ocular opical quality[J]. J Cataract Refract Surg,2004,30(7):1598-1599.
[7]
Vilaseca M, Peris E, Pujol J, et al. Intra-and intersession repeatability of double-pass instrument[J]. Optom Vis Sci,2010, 87(9):675-681.
[8]
Cuell JL, Pujol J, Arjona M, et al. Optical quality analysis system: instrument for objective clinical evaluation of ocular opical quality[J]. J Cataract Refract Surg,2004,30(7):1598-1599.
[9]
Saad A, Saab M, Gatinel D. Repeatability of measurements with a double-pass system[J]. J Cataract Refract Surg,2010,36(1):28-33.
[10]
Martinez-Roda JA, Vilaseca M, Ondategui JC, et al. Optical quality and intraocular scattering in a healthy young population[J]. Clin Exp Optom,2011,94(2):223-229.
[11]
Diaz-Douton F, Benito A, Pujol J. Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument[J]. Invest Ophthalmol Vis Sci,2006,47 (4):1710-1716.
Vilaseca M, Romero MJ, Arjona M, et al. Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system[J]. Br J Ophthalmol,2012,96(9):1204-1210.
[15]
Lee K, Ahn JM, Kim EK, et al. Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia[J]. Graefes Arch Clin Exp Ophthalmol,2013,251(9):2163-2169.
[16]
Kamiya K, Umeda K, Kobashi H, et al. Effect of aging on optical quality and intraocular scattering using the double-pass instrumeng[J]. Curr Eye Res,2012,37(10):884-888.