Objective To assess the effect on anterior chamber angle, corneal endothelial and adjacent tissue after implantation of phakic posterior chamber implantable collamer lens (PPC-ICL) for the correction of high myopia. Methods In this prospective, nonrandomized clinical study, 106 consecutive eyes of 58 patients with high myopic received ICL implantation between January 2011 and June 2013 in the Ningxia Eye Hospital. Uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), intraocular pressure, corneal endothelial cell count were measured preoperatively and at 1 month, 6 months and 12 months postoperatively. The ultrasound biomicroscopy (UBM) was used to observe the depth of anterior chamber (ACD) vault, angle opening distance 500 microns from the scleral spur (AOD500), trabecular-iris angle (TIA) at point 2, 4, 8 and 10 respectively. The repeated measurement ANOVA was used to analyzed statistical data. Results The postoperative UCVA was equally or higher compare with preoperative BCVA in all patients. Intraocular pressure and corneal endothelial cell count were no statistically significant difference between pre- and postoperative (P>0.05). The postoperaive ACD, AOD500 and TIA value were decreased significantly than preoperative at 1 month (F=12.372, 21.393, 22.076, 21.154, 21.763, 19.471, 19.823, 19.836, 19.247, P<0.05). But there were no statistically significant difference of ACD, AOD500, vault and TIA between 1-month and 6-month, 12-month postoperatively. No pupillary block glaucoma or anterior capsule opacification occurred during the follow-up. Conclusion The structure of anterior chamber angle was stable and corneal endothelial cell was no obvious decrease postoperatively during 1 year follow-up.
容维宁,孙燕,郭慧青,徐惠芳,贾沁,梁静,殷莉,周玲婕,盛迅伦. 有晶状体眼后房型人工晶状体植入术后眼前节形态学观察[J]. 中华眼视光学与视觉科学杂志, 2015, 17(8): 458-462.
Rong Weining,Sun Yan,Guo Huiqing,Xu Huifang,Jia Qin,Liang Jing,Yin Li,Zhou Lingjie,Sheng Xunlun. Changes of ocular anterior segment on morphology after implantation of the implantable collamer lens for high myopia. Chinese Journal of Optometry Ophthalmology and Visual science, 2015, 17(8): 458-462. DOI: 10.3760/cma.j.issn.1674-845X.2015.08.003
Doors M, Cals DW, Berendschot TT, et al. Influence of anterior chamber morphometrics on endothelial cell changes after phakic intraocular lens implantation[J]. J Cataract Refract Surg,2008, 34(12):2110-2118.
[2]
van Eijden R, de Vries NE, Cruysberg LP, et al. Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation[J]. J Cataract Refract Surg,2009, 35(4):774-777.
[3]
Lackner B, Pieh S, Schmidinger G, et al. Outcome after treatment of ametropia with implantable contact lenses[J]. Ophthalmology,2003,110(11):2153-2161.
[4]
Dejaco-Ruhswurm I, Scholz U, Pieh S, et al. Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses[J]. J Cataract Refract Surg,2002,28(9):1589-1593.
[5]
Lema I, Durán JA, Ruiz C, et al. Inflammatory response to contact lenses in patients with keratoconus compared with myopic subjects[J]. Cornea,2008,27(7):758-763.
[6]
O′Keefe M, Kirwan C. Laser epithelial keratomileusis in 2010—a review[J]. Clin Experiment Ophthalmol,2010,38(2): 183-191.
[7]
Nachiketa N, Munshi V. Refractive lensectomy in extreme myopia[J]. J Cataract Refract Surg,2001,27(12):1900-1901.
[8]
Colin J, Robinet A, Cochener B. Retinal detachment after clear lens extraction for high myopia-seven-year follow-up[J]. Ophthalmology,1999,106(12):2281-2284.
Fernandes P, González-Méijome JM, Madrid-Costa D, et al. Implantable collamer posterior chamber intraocular lenses: a review of potential complications[J]. J Refract Surg,2011,27(10):765-776.
[11]
Igarashi A, Shimizu K, Kamiya K. Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia[J]. Am J Ophthalmol,2014,157(3):532-539.
[12]
Gonvers M, Bornet C, Othenin-Girard P. Implantable contact lens for moderate to high myopia: relationship of vaulting to cataract formation[J]. J Cataract Refract Surg,2003,29(5):918-924.
[13]
Lim DH, Lee MG, Chung ES, et al. Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth[J]. Am J Ophthalmol,2014,158(3):447-454.
Pavlin CJ, Harasiewicz K, Foster FS. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes[J]. Am J Ophthalmol,1992,113(4):381-389.
[16]
Pavlin CJ, Harasiewicz K, Sherar MD, et al. Clinical use of ultrasound biomicroscopy[J]. Ophthalmology,1991,98(3):287-295.