Changes in the central vault after collamer lens implantation and its impact |
Xu Jing*,Luo Yan,Lin Yannan,Li Ying |
Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Science & Peking Union Medical College, Beijing 100730, China |
|
|
Abstract
Objective To investigate changes in the central vault one year after collamer lens (PPC-ICL) implantation surgery and its impact factors. Methods This retrospective study included 134 eyes of 69 patients. Mean spherical equivalent (SE) was -12.28±3.80 diopters (D) (range: -5.00 to -20.50 D) for those who underwent PPC-ICL implantation. In addition to a complete ophthalmologic examination, the central vault was measured with Topcon OCT and evaluated during the follow-up period (1 month to 1 year, postoperatively). Data were analyzed using repeated measures ANOVA, multiple linear regression analysis. Results Within the first year, the mean central vault dropped from 576±247 µm (range 112 to 1 131 µm) to 512±238 µm (range 159 to 1 168 µm). This decrease was significant by 65±85 µm (range -210 to 135 µm) (F=7.11, P<0.01) within this period. Regression fomula showed 1 month and 1 year postoperation vault was negative related with SE, but positive related with diopter and overall length of the PPL-ICL (R2=0.389, 0.434, F=17.15, 21.15, P<0.01). White-to-white (WTW) diameter and the overall length of the PPC-ICL (R2=0.500, F=7.99, P<0.05) were factors that were significantly associated with a decrease in the vault between 1 year and 1 month postoperation. Conclusion A significant reduction in the central vault occurred from 1 month to 1 year, postoperatively. The decrease in the vault was more pronounced in eyes with a larger WTW and a smaller overall diameter.
|
Received: 10 October 2016
|
Corresponding Authors:
Luo Yan, Email: lawyan@sina.com
|
|
|
|
[1] |
Kojima T, Maeda M, Yoshida Y, et al. Posterior chamber phakic implantable collamer lens: changes in vault during 1 year[J]. J Refract Surg,2010,26(5):327-332. DOI:10.3928/1081597X-200906 17-11.
|
[2] |
Lackner B, Pieh S, Schmidinger G, et al. Outcome after treatment of ametropia with implantable contact lenses[J]. Ophthalmology, 2003,110(11):2153-2161. DOI:10.1016/S0161-6420(03)00830-3.
|
[3] |
Maeng HS, Chung TY, Lee DH, et al. Risk factor evaluation for cataract development in patients with low vaulting after phakic intraocular lens implantation[J]. J Cataract Refract Surg, 2011,37(5):881-885. DOI:10.1016/j.jcrs.2010.11.037.
|
[4] |
Schmidinger G, Lackner B, Pieh S, et al. Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients[J]. Ophthalmology,2010,117(8):1506-1511. DOI: 10.1016/j.ophtha.2009.12.013.
|
[5] |
Choi KH, Chung SE, Chung TY, et al. Ultrasound biomicroscopy for determining visian implantable contact lens length in phakic IOL implantation[J]. J Refract Surg,2007,23(4):362-367.
|
[6] |
Alfonso JF, Lisa C, Abdelhamid A, et al. Three-year follow-up of subjective vault following myopic implantable collamer lens implantation[J]. Graefes Arch Clin Exp Ophthalmol,2010,248(12):1827-1835. DOI:10.1007/s00417-010-1322-0.
|
[7] |
Cao X, Tong J, Wang Y, et al. Long-term ultrasound biomicroscopy observation of position changes of a copolymer posterior chamber phakic intraocular lens[J]. J Cataract Refract Surg,2014,40(9):1454-1461. DOI:10.1016/j.jcrs.2013.12.022.
|
[8] |
Benda F, Filipová L, Filipec M. Correction of moderate to high hyperopia with an implantable collamer lens: medium-term results[J]. J Refract Surg,2014,30(8):526-533. DOI:10.3928/1081597X-20140711-05.
|
[9] |
Alfonso JF, Fernandez-Vega L, Lisa C, et al. Long-term evaluation of the central vault after phakicCollamer?誖 lens (ICL) implantation using OCT[J]. Graefes Arch Clin Exp Ophthalmol,2012,250(12):1807-1812. DOI:10.1007/s00417-012-1957-0.
|
[10] |
Petternel V, K?觟ppl CM, Dejaco-Ruhswurm I, et al. Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye[J]. Ophthalmology,2004,111(2):325-331. DOI:10.1016/j.ophtha.2003.05.013.
|
[11] |
Schmidinger G, Lackner B, Pieh S, et al. Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients[J]. Ophthalmology,2010,117(8):1506-1511. DOI: 10.1016/j.ophtha.2009.12.013.
|
[12] |
Alfonso JF, Ferrer-Blasco T, González-Méijome JM, et al. Pupil size, white-to-white corneal diameter, and anterior chamber depth in patients with myopia[J]. J Refract Surg,2010,26(11):891-898. DOI:10.3928/1081597X-20091209-07.
|
[13] |
余克明,罗汇慧,庄菁,等. 有晶状体眼后房型人工晶状体植入术后患者在不同瞳孔状态下的眼前段变化[J]. 中华眼视光学与视觉科学杂志,2012,14(6):357-359. DOI:10.3760/cma.j.issn.1674-845X.2012.06.009.
|
[14] |
Lee DH, Choi SH, Chung ES, et al. Correlation between preoperative biometry and posterior chamber phakicVisian Implantable Collamer Lens vaulting[J]. Ophthalmology,2012,119(2):272-277. DOI:10.1016/j.ophtha.2011.07.047.
|
[15] |
Lindland A, Heger H, Kugelberg M, et al. Vaulting of myopic and toric Implantable Collamer Lenses during accommodation measured with Visante optical coherence tomography[J]. Ophthalmology,2010,117(6):1245-1250. DOI:10.1016/j.ophtha.2009. 10.033.
|
[16] |
杜改萍,黄一飞,余继峰,等. 有晶状体眼后房型人工晶状体拱高相关因素分析[J]. 中国实用眼科杂志,2011,29(1):36-39. DOI:10. 3760/cma.j.issn.1006-4443.2011.01.011.
|
[17] |
曹信芳,汪阳,沈晔,等. 有晶状体眼后房型人工晶状体总长度选择的回顾性分析[J]. 中华眼科杂志,2013,49(3):235-241. DOI:10. 3760/cma.j.issn.0412-4081.2013.03.010.
|
|
|
|