|
|
Z-adjust topography-Guided Laser in Situ Keratomileusis (LASIK) for eccentric cutting induced by LASIK keratorefractive surgery |
Zhen Li,Gaiping Du,Yifei Huang |
Department of Ophthalmology, Chinese PLA, the 401th Hospital, Qingdao 266071, China
Department of Ophthalmology, Chinese PLA General Hospital, Beijing 100853, China |
|
|
Abstract Objective: To evaluate the clinical efficacy of Z-adjust topography-guided customized laser in situ keratomileusis (LASIK) for eccentric cutting induced by LASIK keratorefractive surgery. Methods:In this retrospective case series study, 10 eyes of 8 patients with eccentric cutting induced by LASIK surgery from June 2008 to December 2014 at Chinese PLA the 401th Hospital were enrolled. The patients were treated with Z-adjust topography-guided LASIK. The uncorrected visual acuity (UCVA), refractive status, corneal Q-value (which describes the corneal aspherical quality), and corneal keratometry were analyzed and compared. Results: The pre-operation UCVA (LogMAR) of all patients was 0.3 to 0.6,and the post-operative UCVA (LogMAR) improved significantly was -0.1 to 0.1. The corneal Q-value increased significantly from 1.26±1.55 diopter (D) (range 0.26 to 2.25 D) pre-operative to 0.28±0.35 D(range -0.27 to 0.50 D) at 3 months post-operative. The corneal keratometry decreased significantly from 40.98±3.56 D (range 39.25 to 43.50 D) to 37.32±1.47 D (range 36.25 to 38.50 D). The scotopic pupil diameter increased significantly from 5.9±0.4 mm (range 5.5 to 6.1 mm) to 6.8±1.1 mm (range 6.0 to 7.4 mm). The Z-adjust range for the X axis was adjusted from +0.005 to +0.052 mm, and for the Y axis, it was adjusted from +0.007 to +0.045 mm. Conclusions: The eccentric cutting of all eyes were corrected by Z-adjust topography-guided customized LASIK surgery, and the visual quality was greatly improved.
|
Received: 19 July 2017
|
Fund: This study was funded by Genenral Project of National Natural Science of China (81670830) |
Corresponding Authors:
Yifei Huang, Department of Ophthalmology, Chinese PLA General Hospital,Beijing 100853, China (Email: 301yk@sina.com)
|
|
|
|
[1] |
张文文, 蔡剑茹, 陈辉. 激光角膜屈光手术中的偏中心问题.中华眼视光学与视觉科学杂志, 2014, 16(5): 315-317. DOI:10.3760/cma.j.issn.1674-845X.2014.05.014.
|
[4] |
刘祖国, 林跃生. 角膜地形图学. 广东: 广东科技出版社, 2001.
|
[5] |
Chen X, Stojanovic A, Zhou W, et al. Transepithelial topography-guided ablation in the treatment of visual disturbancesin LASIK flap or interface complications. J Refract Surg, 2012, 28(2): 120-126. DOI: 10.3928/1081597X-20110926-01.
|
[6] |
Pasquali T, Krueger R. Topography-guided laser refractive surgery. Curr Opin Ophthalmol, 2012, 23(4): 264-268. DOI:10.1097/ICU.0b013e328354adf0.
|
[7] |
陈开建, 白继, 刘莛, 等. 角膜地形图引导FS-LASIK治疗非对称性角膜散光的疗效观察. 中华眼视光学与视觉科学杂, 2016, 18(7): 394-398. DOI:10.3760/cma.j.issn.1674845X.2016.07.003.
|
[8] |
于靖, 陈辉. 波前引导的准分子激光原位角膜磨镶术矫正准分子激光角膜切削术偏中心切削一例. 中华眼科杂志, 2005,6(41): 547-549. DOI: 10.3760/j:issn:0412-4081.2005.06.016.
|
[9] |
Lin DT, Holland SR, Rocha KM, et a1. Method for optimizing topography-guided ablation of highly aberrated eyes with the ALLEGRETTO WAVE Excimer Laser. J Refract Surg, 2008, 24(4):S439-445.DOI: 10.3760/cma.j.issn.2095-1477.2012.03.011.
|
[10] |
吴震, 荆翠红, 韩九娥, 等. 角膜地形图引导下准分子激光矫正角膜不规则散光及不对称性散光. 中华眼外伤职业眼病杂志, 2012, 34(3): 195-198. DOI: 10.3760/cma.j.issn.2095-1477.
|
[2] |
Moreno-Barriuso E, Lloves JM, Marcos S, et al. Ocular aberrations before and after myopic corneal refractive surgery:LASIK-induced changes measured with laser ray tracing. Invest
|
|
Ophthalmol Vis Sci, 2001, 42(6): 1396-1403. DOI: 10.3760/cma.j.issn.2095-1477.2008.08.007
|
[3] |
刘美光, 马玉娜, 李爱华, 等. 眼球跟踪系统减少LASIK术后切削区偏中心的作用. 眼外伤职业眼病杂志, 2008, 30(8): 612-614. DOI: 10.3760/cma.j.issn.2095-1477.2008.08.007.
|
20 |
12.03.011.
|
[11] |
赵宏, 李彩红, 丁相奇, 等. 由Oculyzer引导的LASIK矫正准分子激光偏中心切削的临床研究. 中华眼外伤职业眼病杂志,2014, 36(3): 185-188. DOI: 10.3760/cma.j.issn.2095-1477.2014.
|
[4] |
刘祖国, 林跃生. 角膜地形图学. 广东: 广东科技出版社, 2001.
|
[5] |
Chen X, Stojanovic A, Zhou W, et al. Transepithelial topography-guided ablation in the treatment of visual disturbancesin LASIK flap or interface complications. J Refract Surg, 2012, 28(2): 120-126. DOI: 10.3928/1081597X-20110926-01.
|
[6] |
Pasquali T, Krueger R. Topography-guided laser refractive surgery. Curr Opin Ophthalmol, 2012, 23(4): 264-268. DOI:10.1097/ICU.0b013e328354adf0.
|
[7] |
陈开建, 白继, 刘莛, 等. 角膜地形图引导FS-LASIK治疗非对称性角膜散光的疗效观察. 中华眼视光学与视觉科学杂, 2016, 18(7): 394-398. DOI:10.3760/cma.j.issn.1674845X.2016.07.003.
|
[8] |
于靖, 陈辉. 波前引导的准分子激光原位角膜磨镶术矫正准分子激光角膜切削术偏中心切削一例. 中华眼科杂志, 2005,6(41): 547-549. DOI: 10.3760/j:issn:0412-4081.2005.06.016.
|
[9] |
Lin DT, Holland SR, Rocha KM, et a1. Method for optimizing topography-guided ablation of highly aberrated eyes with the ALLEGRETTO WAVE Excimer Laser. J Refract Surg, 2008, 24(4):S439-445.DOI: 10.3760/cma.j.issn.2095-1477.2012.03.011.
|
[10] |
吴震, 荆翠红, 韩九娥, 等. 角膜地形图引导下准分子激光矫正角膜不规则散光及不对称性散光. 中华眼外伤职业眼病杂志, 2012, 34(3): 195-198. DOI: 10.3760/cma.j.issn.2095-1477.
|
03 |
007.
|
20 |
12.03.011.
|
[11] |
赵宏, 李彩红, 丁相奇, 等. 由Oculyzer引导的LASIK矫正准分子激光偏中心切削的临床研究. 中华眼外伤职业眼病杂志,2014, 36(3): 185-188. DOI: 10.3760/cma.j.issn.2095-1477.2014.
|
03 |
007.
|
|
|
|