Change of Total Ocular High Order Aberrations and Corneal Biomechanical Effects by Small Incision Lenticule Extraction |
Kangjun Li1 , Shanshan Wang2 , Qingyun Li2 , Qing Yu2 , Xiaocui Song2 , Yaxin Li2 |
1The Aier Eye Institute of Central South University, Changsha 410083, China 2The Xi'an Aier Eye Hospital, Xi'an 710000, China |
|
|
Guide |
|
Abstract Objective: To investigate the change of high order aberration of total eye and corneal biomechanics in patients undergoing small incision lenticule extraction (SMILE) and to examine the higher order aberrations(HOA) in relation to corneal biomechanical changes. Methods: Prospective clinical study. A total of 160 patients underwent SMILE in Xi 'an Aier Eye Hospital were selected from March 2019 to March 2020. The cornea and total spherical aberration, coma, trefoil and total HOA were measured by iTrace. Corvis-ST was used to measure the corneal stiffness parameters at the first applanation (SP-A1) and deformation amplitude (DA). Paired t-test, One-way ANOVA and Pearson correlation analysis were used for changes of HOA (Corneal ΔHOA, Total ocular ΔHOA) and corneal biomechanical parameters (ΔSP-A1,ΔDA). Results: Six months later, 150 patients (295 eyes) were in follow-up team (follow-up rate, 94%) and the corneal HOA was 0.37±0.01 μm and the total ocular HOA was 0.24±0.01 μm. The corneal HOA was increased by 15.63% and the total ocular HOA was decreased by 35.14% with statistically significant differences (t=3.76, P=0.002; t=10.04, P=0.001). SP-A1 (77.29±11.86)mmHg/mm was decreased by 29.6% and DA (1.19±0.68) mm was increased by 10.4% with statistically significant differences (t=32.98,20.62, P<0.001). ΔSP-A1, ΔDA and total ocular ΔHOA were significantly correlated (r=0.19, P<0.001; r=0.17, P=0.002). Conclusions: The total ocular HOA decreased after SMILE and the alterations in corneal morphology caused by biomechanics may affect HOA.
|
Received: 01 September 2021
|
|
Fund:Natural Science Foundation of Hunan Province (2021JJ30048); Aier Eye Group Research Project Fund (AF1909D4, AF2009D8); Aier Eye Group Clinical Scientific Research Fund (AR2109D3) |
Corresponding Authors:
Kangjun Li, the Aier Eye Institute of Central South University, Changsha 410083, China
|
|
|
|
[1] |
Alió Del Barrio JL, Vargas V,Al-Shymali O, et al. Small incision lenticule extraction (SMILE) in the correction of myopic astigmatism: outcomes and limitations - an update. Eye Vis(Lond), 2017, 4(1): 26. DOI: 10.1186/ s40662 -017-0091-9.
|
[2] |
Blum M, Kunert KS, Sekundo W. Historical Overview of the Clinical Development of the Small Incision Lenticule Extraction Surgery (SMILE). Klin Monbl Augenheilkd, 2017, 234(1):117- 122. DOI: 10.1055/s-0042-115944.
|
[3] |
李康寯, 张凌子, 宋小翠, 等. SMILE和ICL矫正中低度近视术后 角膜前后表面和总角膜高阶像差的变化. 国际眼科杂志, 2018, 18(12): 2289-2292. DOI: CNKI: SUN: GJYK.0.2018-12-049.
|
[4] |
Li K, Wang Z, Zhang D, et al.Visual outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus. J Cataract Refract Surg, 2020, 46(10): 1339-1345. DOI: 10.1097/ j.jcrs.0000000-000000262.
|
[5] |
Siedlecki J, Schmelter V, Schworm B, et al. Corneal wavefront aberrations and subjective quality of vision after small incision lenticule extraction.Acta ophthalmol, 2020, 98(7): e907-e913. DOI: 10.1111/aos.14420.
|
[6] |
Fang L, Ma W, Wang Y, et al.Theoretical Analysis of Wave Front Aberrations Induced from Conventional Laser Refractive Surgery in a Biomechanical Finite Element Model. Invest Ophthalmol Vis Sci, 2020, 61(5): 34. DOI: 10.1167/iovs. 61.5.34.
|
[7] |
A ca A, Tülü B, Ya a D, et al. Long-term (5 years) follow-up of small-incision lenticule extraction in mild-to-moderate myopia. J Cataract Refract Surg, 2019, 45(4): 421-426. DOI: 10.1016/ j.jcrs.2018.11.010.
|
[8] |
Guo H, Hosseini-Moghaddam SM, Hodge W. Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: a systematic review and meta-analysis. BMC Ophthalmol, 2019, 19(1): 167. DOI: 10.1186/s12886-019-1165-3.
|
[9] |
Ang M, Gatinel D, Dan ZR, et al.Refractive surgery beyond 2020. Eye(Land), 2021, 35(2): 362-382. DOI: 10.1038/s41433- 020-1096-5.
|
[10] |
Randleman JB. Small Incision Lenticule Extraction (SMILE): What Now? What Next? Ophthalmology, 2020, 127(8): 1035- 1036. DOI: 10.1016/j.ophtha.2020.03.013. [11] Shetty R, Francis M, Shroff R, et al. Corneal Biomechanical Changes and Tissue Remodeling After SMILE and LASIK. Invest Ophthalmol Vis Sci, 2017, 58(13): 5703-5712. DOI: 10.1167/iovs.17-22864.
|
[12] |
Francis M, Khamar P, Shroff R, et al. In Vivo Prediction of Air Puff Induced Corneal Deformation Using LASIK, SMILE, and PRK Finite Element Simulations. Invest Ophthalmol Vis Sci, 2018, 59(13): 5320-5328. DOI: 10. 1167/iovs.18-2470.
|
[13] |
张明悦, 张丰菊, 宋彦铮, 等. SMILE手术前后角膜形态学和 生物力学特性变化的研究. 中华眼科杂志, 2020, 56(2): 103- 109. DOI: 10.3760/cma.j.issn.0412-4081. 2020.02.006.
|
[14] |
Shetty R, Matalia H, Nandini C, et al. Wavefront-Guided LASIK Has Comparable Ocular and Corneal Aberrometric Outcomes but Better Visual Acuity Outcomes Than SMILE in Myopic Eyes. J Refract Surg, 2018, 34(8): 527-532. DOI: 10.3928/1081597X-20180607-02.
|
[15] |
郑燕, 周跃华, 张晶,等. FS-LASIK、WF-LASIK与SMILE术 后视觉质量比较的研究. 中华眼科杂志, 2020, 56(2): 118-125. DOI: 10.3760/cma.j.issn.0412-4081. 2020.02.007.
|
[16] |
武志清, 王雁, 张琳, 等. 飞秒激光小切口角膜基质内透镜取 出术与飞秒激光LASIK术后高阶像差改变的对比研究. 中 华眼科杂志, 2015, 51(3): 193-201. DOI: 10.3760 /cma. j.issn.0412-4081.2015.03.009.
|
[17] |
Won JB, Kim SW, Kim EK, et al. Comparison of internal and total optical aberrations for 2 aberrometers: iTrace and OPD scan. Korean J Ophthalmol, 2008, 22(4): 210-213. DOI: 10.3341/kjo.2008.22.4.210.
|
[18] |
Xu Z, Hua Y, Qiu W, et al. Precision and agreement of higher order aberrations measured with ray tracing and Hartmann Shack aberrometers. BMC Ophthalmol, 2018, 18(1):18. DOI: 10.1186/s12886-018-0683-8.
|
[19] |
Denoyer A, Ricaud X, Went CV, et al. Influence of corneal biomechanical properties on surgically induced astigmatism in cataract surgery. J Cataract Refract Surg, 2013, 39(8): 1204- 1210. DOI: 10.1016/j.jcrs.2013.02.052.
|
[20] |
Piñero DP, Alio JL, Barraquer RI, et al. Corneal biomechanical changes after intracorneal ring segment implantation in keratoconus. Cornea, 2012, 31(5): 491-499. DOI:10.1097/ ICO.0b013e31821ee9f4.
|
|
|
|