Effect of Kappa Angle on Visual Quality after Regional Refraction MIOL Implantation in Cataract Patients with High Myopia |
Wei He, Lu Chang, Qingying Zhao, Pengfei Jiang, Xudong Huang, Jing Gao |
Weifang Eye Hospital, Weifang 261000, China |
|
|
Guide |
|
Abstract Objective: Preoperative Kappa angle measurement was performed to evaluate the influence of Kappa angle on visual quality of cataract patients with high myopia after regional refractive multifocal intraocular lens (MIOL) implantation. Methods: In this retrospective case series study, patients who underwent phacoemulsification combined with regional refractive MIOL implantation in Weifang Eye Hospital due to high myopia complicated with cataract from October 2018 to October 2019 were collected. There were 53 cases (53 eyes), aged 42 -66 years (average age: 52.2±6.3 years old). Patients were divided into group A (0
|
Received: 18 October 2021
|
|
Fund:Weifang Science and Technology Development Plan Project (2019YX043) |
Corresponding Authors:
Jing Gao, Weifang Eye Hospital, Weifang 261000, China (Email: yikun0815@163.com)
|
|
|
|
[1] |
Abell RG, Davies PEJ, Phelan D, et al. Anterior capsulotomy integrity after femtosecond laser-assisted cataract surgery. Ophthalmology, 2014, 121(1): 17-24. DOI: 10.1016/ j.ophtha.2013.08.013.
|
[2] |
Garzón N, García-Montero M, López-Artero E, et al.Influence of angle κ on visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens. J Cataract Refract Surg, 2020, 46(5): 721-727. DOI: 10.1097/j.jcrs.0000000000000156.
|
[3] |
胡春玲, 张晓农, 惠延年. 老年性白内障晶状体核硬度及相 关因素研究. 中华眼科杂志, 2000, 36( 5):l337-1340. DOI: 10.3760/j:issn:0412-4081.2000.05.005.
|
[4] |
El-Nafees R, Moawad A,Kishk H, et al. Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery. Saudi J Ophthalmol, 2010, 24(3): 77-80. DOI: 10.1016/j.sjopt.2010.03.006.
|
[5] |
Yu AY, Lu T, Pan AP, et al. Assessment of tear film optical quality dynamics. Invest Ophthalmol Vis Sci, 2016, 57(8): 3821- 3827. DOI: 10.1167/iovs.15-18985.
|
[6] |
单玉琴, 郑广瑛, 李莉, 等. 区域折射型多焦点人工晶状体植 入术与单焦点人工晶状体植入术中长期视觉质量比较. 中 华实验眼科杂志, 2020, 38(4): 348-354. DOI: 10.3760/cma. j.cn115985-20190902-00379.
|
[7] |
McNeely RN, Pazo E, Spence A, et al. Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens. J Cataract Refract Surg, 2017, 43(5): 633-638. DOI: 10.1016/ j.jcrs.2017.01.025.
|
[8] |
Fu Y, Kou J, Chen D, et al. Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses. J Cataract Refract Surg, 2019, 45(9): 1258- 1264. DOI: 10.1016/j.jcrs.2019.04.003.
|
[9] |
Eldanasoury A, Tolees S, Bains HS. Clinical outcomes after phacoemulsification with implantation of trifocal and toric trifocal intraocular lenses. J Refract Surg, 2021, 37(6): 372-379. OI: 10.3928/1081597X-20210217-01
|
[10] |
Liu Y, Gao Y, Liu R, et al. Influence of angle kappa-customized implantation of rotationally asymmetric multifocal intraocular lens on visual quality and patient satisfaction. Acta Ophthalmol, 2020, 98(6): e734-e742. DOI: 10.1111/aos.14356.
|
[11] |
Wang R, Long T, Gu X, et al. Changes in angle kappa and angle alpha before and after cataract surgery. J Cataract Refract Surg, 2020, 46(3): 365-371. DOI: 10.1097/j.jcrs.0000000000000063.
|
[12] |
Luo J, Liu Y, Wang F, et al. Effect of the kappa angle on depth of focus after implantation of the TECNIS Symfony intraocular lens. Int Ophthalmol, 2021, 41(7): 2513-2520. DOI: 10.1007/ s10792-021-01809-x.
|
[13] |
Karhanová M, Pluhá ek F,Ml ák P, et al. The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model. Acta Ophthalmol, 2015, 93(2): e123-e128. DOI: 10.1111/aos.12521.
|
[14] |
温凯, 张红, 孙靖, 等. kappa角在人群中的发布: 基于iTrace 像差仪的研究.眼科新进展, 2018, 38( 3): 265-268. DOI: 10.13389/i.cnki.rao.2018.0062.
|
[15] |
Qi Y, Lin J, Leng L, et al. Role of angle κ in visual quality in patients with a trifocal diffractive intraocular lens. J Cataract Refract Surg, 2018, 44(8): 949-954. DOI: 10.1016/ j.jcrs.2018.05.026.
|
[16] |
高婧, 常鲁, 姜鹏飞, 等. OQSAⅡ评估高度近视并发白内障 患者植入不同MIOL术后视觉质量.国际眼科杂志, 2021, 21 ( 7): 1284-1287. DOI: 10.3980/j.issn.1672-5123.2021.7.32.
|
[17] |
Liu H, Li FF, Xia HJ, et al. Visual quality after implantation of trifocal intraocular lenses in highly myopic eyes with different axial lengths. Int J Ophthalmol, 2021, 14(3):371-377. DOI: 10.18240/ijo.2021.03.06.
|
[18] |
徐婷, 王静, 陶黎明. 两种角膜屈光手术后早期客观视觉质 量分析. 国际眼科杂志, 2020, 20(4): 722-725. DOI: 10.3980/ j.issn.1672-5123.2020.4.33.
|
[19] |
陈祥菲, 赵明, 陆燕, 等. SMILE 和 Epi-LASIK 术后1年患者 视觉质量及眼内散射情况——基于双通道视觉质量分析系 统(OQAS)的对比研究. 眼科新进展, 2020, 40(6): 554-558. DOI: 10.13389 /j.cnki.rao.2020.0127.
|
[20] |
陈琛, 叶剑, 黄婵娟, 等. 不同Kappa角多焦点人工晶状 体植入术后的视觉质量 . 中华眼视光学与视觉科学杂 志, 2016, 18(5): 298-301. DOI: 10.3760/cma.j.issn.1674- 845X.2016.05.010.
|
[21] |
Cillino S, Casuccio A, Di Pace F, et al. One-year outcomes with new-generation multifocal intraocular lenses. Ophthalmology, 2008, 115(9): 1508-1516. DOI: 10.1016/j.ophtha.2008.04.017.
|
|
|
|