Early changes in anterior chamber parameters after laser in situ keratomileusis with an Allegro Oculyzer system |
YE Zheng-hui,XU Zhi-wei,LU Li-rong,QIU Zhao-xia,CHENG Jia,HONG Yang,XU De-jian |
|
|
Abstract Objective To investigate early changes in anterior chamber parameters with the Allegro Oculyzer system after laser in situ keratomileusis (LASIK). Methods Thirty-nine patients (77 eyes) were recruited for this prospective self-control study. An Allegro Oculyzer anterial segment analysis system was used to measure the parameters of the anterior chamber (i.e. the anterior chamber volume, the anterior chamber angle of the four quadrants, and the central and peripheral anterior chamber depths) before and after LASIK. The Wilcoxon signed rank test was used for data analysis. Results Before surgery, the posterior corneal tangential curvature, the anterior chamber volume, the anterior chamber angle(average/superior/inferior/nasal/temporal), and the central and peripheral anterior chamber depths (superior/inferior/nasal/temporal) were: 6.19±0.23 D, 207±30.2 mm3, 40.4°±4.53°, 33.8°±8.57°, 33.9°±4.72°, 42.9°±5.00°, 42.9°±4.68°, 3.23±0.23 mm, 1.51±0.20 mm, 1.43±0.24 mm, 0.98±0.20 mm, and 1.03±0.21 mm, respectively. Seven days after the surgery, the parameters had changed to: 6.19±0.22 D,197±31.1 mm3, 40.6°±4.91°, 34.8°±8.15°, 33.9°±4.72°, 41.3°±5.32°, 43.5°±4.25°, 3.13±0.24 mm, 1.45±0.22 mm, 1.36±0.28 mm, 0.93±0.20 mm, and 0.96±0.21 mm, respectively. The differences between the anterior chamber volume and the central and peripheral anterior chamber depths were statistically significant (Z=-5.466, -7.352, -2.614, -2.546, -2.203, -3.327, P<0.05). Conclusion The anterior chamber volume and the central and peripheral anterior chamber depths decreased soon after LASIK was performed with the Allegro Oculyzer system. The change in the central anterior chamber depth was greater than that of the peripheral anterior chamber depth.
|
Received: 28 July 2012
|
Corresponding Authors:
YE Zheng-hui
|
|
|
|
[1] |
黄钰森,姚瞻. 眼前节分析系统检查中国人正常房角宽度和前房深度. 中国实用眼科杂志,2002,20:373-375.
|
[2] |
Buehl W, Stojanac D, Sacu S, et al. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Am J Ophthalmol,2006,141:7-12.
|
[3] |
何燕玲,元力,黎晓新. Pentacam三维眼前节分析诊断系统对近视眼眼前节的测量. 眼科研究,2007,25:872-874.
|
[4] |
黄锦海,温岱宗,陈世豪,等. Pentacam系统测量LASIK术后眼前节参数重复性的研究. 眼科研究,2009,27:70-71.
|
[5] |
李莹,李悦,罗岩,等. Pentacam前节分析系统测量角膜厚度、地形图及屈光手术后角膜后表面的研究. 山东大学耳鼻喉眼学报,2011,25:82-88.
|
[6] |
Nishimura R, Negishi K, Saiki M, et al. No forward shifting of posterior corneal surface in eyes undergoing LASIK. Ophthalmology,2007,114:1104-1110.
|
[7] |
Cummings AB, Mascharka N. Outcomes after topography-based LASIK and LASEK with the wavelight oculyzer and topolyzer platforms. J Refract Surg,2010,26:478-485.
|
[8] |
Lam AK, Chan R, Woo GC, et al. Intra-observer and inter-observer repeatability of anterior eye segment analysis system (EAS-1000) in anterior chamber configuration. Ophthalmic Physiol Opt,2002,22:552-559.
|
[9] |
羊薇,邓应平,谢敏. 准分子激光原位角膜磨镶术后角膜后表面Diff值的变化. 中华眼视光学与视觉科学杂志,2010,12:131-133.
|
|
|
|