Small incision lenticule extraction (SMILE) has emerged as a new kind of corneal refractive surgery for correct myopia and astigmatism. SMILE is widely concerned because its incision is small and it can maintain corneal structure better compared with laser in situ keratomileusis (LASIK). Many studies now focus on visual outcomes, optical quality, corneal biomechanical changes after SMILE as well as on complications associated to this technique. Simultaneously, the reuse of the refractive lenticules has make it possible to correct hyperopia with SMILE, which will become the heat spot in the future. This paper reviews the recent research progress on SMILE.
谭倩,马代金. SMILE的研究进展[J]. 中华眼视光学与视觉科学杂志, 2017, 19(4): 251-256.
TAN Qian,MA Daijin.. Research advances in SMILE. Chinese Journal of Optometry Ophthalmology and Visual science, 2017, 19(4): 251-256. DOI: DOI:10.3760/cma.j.issn.1674-845X.2017.04.011
Liu M, Chen Y, Wang D, et al. Clinical outcomes after SMILE and femtosecond laser-assisted LASIK for myopia and myopic astigmatism: A prospective randomized comparative study[J]. Cornea, 2016, 35(2): 210-216. DOI: 10. 1097/ICO.0000 000000000707.
[6]
Pedersen IB, Ivarsen A, Hjortdal J. Three-year results of small incision lenticule extraction for high myopia: refractive outcomes and aberrations[J]. J Refract Surg, 2015, 31(11): 719- 724. DOI: 10.3928/1081597X-20150923-11.
[7]
Blum M, T?覿ubig K, Gruhn C, et al. Five-year results of small incision lenticule extraction (ReLEx SMILE)[J]. Br J Ophthalmol, 2016, 100(9): 1192-1195. DOI: 10.1136/bjophthalmol- 2015-306822.
[8]
Chan TC, Ng AL, Cheng GP, et al. Vector analysis of astigmatic correction after small-incision lenticule extraction and femtosecond-assisted LASIK for low to moderate myopic astigmatism[J]. Br J Ophthalmol, 2016, 100(4): 553-559. DOI: 10. 1136/bjophthalmol-2015-307238.
[9]
Kobashi H, Kamiya K, Ali MA, et al. Comparison of astigmatic correction after femtosecond lenticule extraction and small- incision lenticule extraction for myopic astigmatism[J]. PLoS One, 2015, 10(4): e0123408. DOI: 10.1371/journal.pone.0123408.
[10]
Zhang J, Wang Y, Chen X. Comparison of moderate- to high- astigmatism corrections using wavefront-guided laser in situ keratomileusis and small-incision lenticule extraction[J]. Cornea, 2016, 35(4): 523-530. DOI: 10.1097/ICO.0000000000000782.
Ganesh S, Gupta R. Comparison of visual and refractive outcomes following femtosecond laser-assisted LASIK with SMILE in patients with myopia or myopic astigmatism[J]. J Refract Surg, 2014, 30(9): 590-596.
[16]
Gyldenkerne A, Ivarsen A, Hjortdal J?覫. Comparison of corneal shape changes and aberrations induced by FS-LASIK and SMILE for myopia[J]. J Refract Surg, 2015, 31(4): 223-229. DOI: 10.3928/1081597X-20150303-01.
Xu L, Wang Y, Li J, et al. Comparison of forward light scatter changes between SMILE, femtosecond laser-assisted LASIK, and epipolis LASIK: results of a 1-year prospective study[J]. J Refract Surg, 2015, 31(11): 752-758. DOI: 10.3928/ 1081597X-20151021-04.
[23]
Reinstein DZ, Archer TJ, Randleman JB. Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction[J]. J Refract Surg, 2013, 29(7): 454-460. DOI: 10.3928/1081597X-20130617- 03.
[24]
Sinha RA, Dupps WJ, Roberts CJ. Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: finite-element analysis[J]. J Cataract Refract Surg, 2014, 40(6): 971-980. DOI: 10.1016/j.jcrs.2013.08.065.
[25]
Wang D, Liu M, Chen Y, et al. Differences in the corneal biomechanical changes after SMILE and LASIK[J]. J Refract Surg, 2014, 30(10): 702-707. DOI: 10.3928/1081597X-20140903- 09.
[26]
Dou R, Wang Y, Xu L, et al. Comparison of corneal biomechanical characteristics after surface ablation refractive surgery and novel lamellar refractive surgery[J]. Cornea, 2015, 34(11): 1441-1446. DOI: 10.1097/ICO.0000000000000556.
[27]
Kamiya K, Shimizu K, Igarashi A, et al. Intraindividual comparison of changes in corneal biomechanical parameters after femtosecond lenticule extraction and small-incision lenticule extraction[J]. J Cataract Refract Surg, 2014, 40(6): 963- 970. DOI: 10.1016/j.jcrs.2013.12.013.
[28]
Mohamed-Noriega K, Riau AK, Lwin NC, et al. Early corneal nerve damage and recovery following small incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) [J]. Invest Ophthalmol Vis Sci, 2014, 55(3): 1823-1834. DOI: 10. 1167/iovs.13-13324.
Xu Y, Yang Y. Dry eye after small incision lenticule extraction and LASIK for myopia[J]. J Refract Surg, 2014, 30(3): 186-190. DOI: 10.3928/1081597X-20140219-02.
[31]
Xia L, Zhang J, Wu J. Comparison of corneal biological healing after femtosecond LASIK and small incision lenticule extraction procedure[J]. Curr Eye Res, 2016, 41(9): 1202-1208. DOI: 10. 3109/02713683.2015.1107590.
[32]
Liu M, Zhang T, Zhou Y, et al. Corneal regeneration after femtosecond laser small-incision lenticule extraction: a prospective study[J]. Graefes Arch Clin Exp Ophthalmol, 2015, 253(7): 1035-1042. DOI: 10.1007/s00417-015-2971-9.
[33]
Denoyer A, Landman E, Trinh L, et al. Dry eye disease after refractive surgery: comparative outcomes of small incision lenticule extraction versus LASIK[J]. Ophthalmology, 2015, 122(4): 669-676. DOI: 10.1016/j.ophtha.2014.10.004.
[34]
Wei S, Wang Y. Comparison of corneal sensitivity between FS-LASIK and femtosecond lenticule extraction (ReLEx flex) or small-incision lenticule extraction (ReLEx smile) for myopic eyes[J]. Graefes Arch Clin Exp Ophthalmol, 2013, 251(6): 1645- 1654. DOI: 10.1007/s00417-013-2272-0.
[35]
Yao P, Zhao J, Li M, et al. Microdistortions in Bowman′s layer following femtosecond laser small incision lenticule extraction observed by Fourier-domain OCT[J]. J Refract Surg, 2013, 29(10): 668-674. DOI: 10.3928/1081597X-20130806-01.
[36]
Luo J, Yao P, Li M, et al. Quantitative analysis of Microdistortions in Bowman′s Layer using optical coherence tomography after SMILE among different myopic corrections[J]. J Refract Surg, 2015, 31(2): 104-109. DOI: 10.3928/1081597X- 20150122-05.
[37]
Li M, Zhao J, Miao H, et al. Mild decentration measured by a Scheimpflug camera and its impact on visual quality following SMILE in the early learning curve[J]. Invest Ophthalmol Vis Sci, 2014, 55(6): 3886-3892. DOI: 10.1167/iovs.13-13714.
[38]
Reinstein DZ, Gobbe M, Gobbe L, et al. Optical zone centration accuracy using corneal fixation-based SMILE compared to eye tracker-based femtosecond laser-assisted LASIK for myopia[J]. J Refract Surg, 2015, 31(9): 586-592. DOI: 10.3928/1081597X-20150820-03.
[39]
Lazaridis A, Droutsas K, Sekundo W. Topographic analysis of the centration of the treatment zone after SMILE for myopia and comparison to FS-LASIK: subjective versus objective alignment[J]. J Refract Surg, 2014, 30(10): 680-686. DOI: 10.3928/ 1081597X-20140903-04.
[40]
Nam SM, Im CY, Lee HK, et al. Accuracy of RTVue optical coherence tomography, Pentacam, and ultrasonic pachymetry for the measurement of central corneal thickness[J]. Ophthalmology, 2010, 117(11): 2096-2103. DOI: 10.1016/j.ophtha.2010.03.002.
[41]
Zhao J, He L, Yao P, et al. Diffuse lamellar keratitis after small-incision lenticule extraction[J]. J Cataract Refract Surg, 2015, 41(2): 400-407. DOI: 10.1016/j.jcrs.2014.05.041.
[42]
Ivarsen A, Asp S, Hjortdal J. Safety and complications of more than 1500 small-incision lenticule extraction procedures[J]. Ophthalmology, 2014, 121(4): 822-828. DOI: 10.1016/j.ophtha. 2013.11.006.
[43]
Riau AK, Angunawela RI, Chaurasia SS, et al. Early corneal wound healing and inflammatory responses after refractive lenticule extraction (ReLEx)[J]. Invest Ophthalmol Vis Sci, 2011, 52(9): 6213-6221. DOI: 10.1167/iovs.11-7439.
[44]
de Paula FH, Khairallah CG, Niziol LM, et al. Diffuse lamellar keratitis after laser in situ keratomileusis with femtosecond laser flap creation[J]. J Cataract Refract Surg, 2012, 38(6): 1014- 1019. DOI: 10.1016/j.jcrs.2011.12.030.
[45]
Thulasi P, Kim SW, Shetty R, et al. Recalcitrant epithelial ingrowth after SMILE treated with a hydrogel ocular sealant[J]. J Refract Surg, 2015, 31(12): 847-850. DOI: 10.3928/1081597X- 20151111-09.
[46]
Mohamed-Noriega K, Toh KP, Poh R, et al. Cornea lenticule viability and structural integrity after refractive lenticule extraction (ReLEx) and cryopreservation[J]. Mol Vis, 2011, 17: 3437-3449.
[47]
Ganesh S, Brar S, Rao PA. Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects[J]. Cornea, 2014, 33(12): 1355- 1362. DOI: 10.1097/ICO.0000000000000276.
[48]
Sun L, Yao P, Li M, et al. The safety and predictability of implanting autologous lenticule obtained by SMILE for hyperopia[J]. J Refract Surg, 2015, 31(6): 374-379. DOI: 10.3928/ 1081597X-20150521-03.