Objective To evaluate monochromatic aberrations (MA) with intraocular lenses (IOLs) using a model eye and Hartmann-Shack aberrometry for measurement. Methods This was a prospective study. Part I: There were 5 different IOL refractive powers (Alcon, SA60AT, +10 D, +15 D, +20 D, +25 D and +30 D). Part II: There were three different +20 D IOLs (SA60AT; Akreos Adapt, Bausch & Lomb; AR40e, AMO). IOLs were tested in a fluid-filled model constructed to replicate the optical conditions of a pseudophakic human eye at different wavelengths of 436, 486, 525, 546, 589, 660 and 710 nm. Those images were caught by CCD and analyzed in MATLAB. A single-factor analysis of variance and Pearson correlation analysis were used for statistical evaluation. Results Part I: Positive correlations were found between IOL refractive power and aberrations for spherical aberrations (SA, Z12, r=0.599, P<0.05), vertical coma (VC, Z7, r=0.817, P<0.05) and horizontal coma (HC, Z8, r=0.488, P<0.05). There was no correlation between IOL refractive power and root mean square of total higher-order aberration (RMSh, r=0.007, P>0.05). No correlation was found between wavelength and aberrations for SA (r=-0.213, P>0.05), VC (r=-0.074, P>0.05), HC (r=0.021, P>0.05) and RMSh (r=-0.322, P>0.05). Part II: There was a significant difference among the 3 IOLs in aberrations, SA (F=74.637, P<0.05), HC (F=6.719, P<0.05) and RMSh (F=11.768, P<0.05). There was no difference in VC (F=1.295, P>0.05). AR40e had the least SA, HC and RMSh of the three IOLs. There was no correlation between wavelength and aberrations for SA (r=0.007, P>0.05), VC (r=-0.312, P>0.05), HC (r=-0.238, P>0.05) and RMSh (r=0.246, P>0.05). Conclusion The MA of IOLs can be evaluated in this model eye. This is useful for an improvement in the optical quality of IOLs and also could be a better choice for patients.
刘丹,沈梅晓,王媛媛,骆亦婷,赵云娥. 基于模型眼的球面人工晶状体单色像差分析[J]. 中华眼视光学与视觉科学杂志, 2013, 15(8): 488-492.
LIU Dan,SHEN Mei-xiao,WANG Yuan-yuan,LUO Yi-ting,ZHAO Yun-e. Research on the monochromatic aberrations of intraocular lenses in a model eye. Chinese Journal of Optometry Ophthalmology and Visual Science, 2013, 15(8): 488-492. DOI: 10.3760/cma.j.issn.1674-845X.2013.08.010
Eppig T, Scholz K, L?觟ffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye. J Cataract Refract Surg,2009,35:1091-1100.
[2]
Drauschke A, Rank E, Auer S, et al. Mechanical eye model for the comparison of optical imaging quality and physiology of human vision. Biomed Tech,2012,57:289-292.
Taketani F, Hara Y. Characteristics of spherical aberrations in 3 aspheric intraocular lens models measured in a model eye. J Cataract Refract Surg,2011,37:931-936.