Study on the Influence of ICL-V4c Implantation on Intraocular Lens Power Calculation
Diliaremu Ailihamu1,2, Xiaowei Gao2, Zhao Li2, Wenjing Li2, Na Hu2, Qingcui Li2, Yan Cai2
1Graduate School of Xinjiang Medical University, Urumqi 830000, China 2Beijing Road Medical District of General Hospital of Xinjiang Military Region, Ophthalmic Center of Chinese PLA, Urumqi 830000, China
Abstract:Objective: To evaluate the influence of posterior chamber intraocular lens ICL-V4c implantation on the intraocular lens (IOL) power calculation. Methods: This was a prospective clinical study. Forty patients (80 eyes) who underwent ICL-V4c implantations in Beijing Road medical District of General Hospital of Xinjiang military Region between December 2020 and June 2021. The IOL-Master 500 biometer was used to measure axial length (AL), keratometry (K1, K2), and anterior chamber depth (ACD) before and 1 day, 1 week, 1 month, 3 months after ICL-V4c implantation. The IOL power was calculated using SRK-T, Holladay , Haigis and Hoffer-Q formulas. Repeated measures ANOVA was used to analyze the data. Results: There was significant difference between the preoperative and postoperative keratometry (K1, K2) (F=34.23, P<0.001; F=14.64, P<0.001). The K1 after the operation were decreased significantly than preoperation (all P<0.001), and showed a gradual uptrend. The K2 after the operation were increased significantly than preoperation (all P<0.05), and showed a gradual downtrend. There was significant difference between the preoperative and postoperative ACD (F=36.90, P<0.001). ACD after the operation were decreased significantly than preoperation (all P<0.001). But there was no significant difference between follow up times after operation, and tended to be stable after operation. There was no significant difference between the preoperative and postoperative AL. The AL at each time point was no significantly difference. The IOL power calculation using SRK-T, Holladay , Haigis and Hoffer-Q formulas without significant differences between pre and postoperation. Conclusions: The results of this study suggest that the measurement of keratometry (K1, K2) and ACD may be affected by ICL-V4c implantation. But, the IOL power calculation using SRK-T, Holladay , Haigis and Hoffer-Q formulas did not change significantly after ICL-V4c implantation.
迪力阿热木·艾力哈木,高晓唯,李钊,等. ICL-V4c植入对人工晶状体度数计算的影响[J]. 中华眼视光学与视觉科学杂志, 2022, 24(10): 767-.
Diliaremu Ailihamu1,2, Xiaowei Gao2,Zhao Li2,et al. Study on the Influence of ICL-V4c Implantation on Intraocular Lens Power Calculation. Chinese Journal of Optometry Ophthalmology and Visual science, 2022, 24(10): 767-. DOI: 10.3760/cma.j.cn115909-20211231-00517