Objective To evaluate the longitudinal chromatic aberrations (LCAs) of spherical, aspherical and toric intraocular lenses (IOLs) under polychromatic light based on a schematic eye. Methods Using Zemax software, a Hwey-Lan Liou schematic eye was set up and the LCAs of the Tecnis ZA9003 IOL, YA60BB IOL, SN60AT IOL and toric IOL were evaluated by the ray tracing method. Results The LCAs were 2.34 D for the toric IOL, 2.35 D for the SN60AT IOL, 1.57 D for the Tecnis ZA9003 IOL and 2.06 D for the YA60BB IOL. The higher Abbe number of the IOL means a lower LCA; SN60AT and T3, T4, T5 toric IOLs displayed the same LCAs. The LCA was larger for short wavelengths compared to long wavelengths. Conclusion The higher the Abbe number is, the smaller the LCA of the IOL. The LCA is the same for lower astigmatism toric IOLs and spherical IOLs.
杨欣,刘丹岩,张斌,杜颖华,郭从容,崔月先. 基于模型眼复曲面IOL纵向色差的评价[J]. 中华眼视光学与视觉科学杂志, 2015, 17(5): 288-291.
Yang Xin,Liu Danyan,Zhang Bin,Du Yinghua,Guo Congrong,Cui Yuexian. Optical performance of the toric intraocular lens based on a schematic eye. Chinese Journal of Optometry Ophthalmology and Visual science, 2015, 17(5): 288-291. DOI: 10.3760/cma.j.issn.1674-845X.2015.05.008
Khan MI, Muhtaseb M. Prevalence of corneal astigmatism in patients having routine cataract surgery at a teaching hospital in the United Kingdom[J]. J Cataract Refract Surg,2011,37(10):1751-1755.
[2]
De Bernardo M, Zeppa L, Cennamo M, et al. Prevalence of corneal astigmatism before cataract surgery in Caucasian patients[J]. Eur J Ophthalmol,2014,24(4):494-500.
[3]
Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm[J]. J Cataract Refract Surg,1995,21(3):313-319.
[4]
Guo H, Atchison DA. Subjective blur limits for cylinder[J]. Optom Vis Sci,2010,87(8):E549-559.
[5]
Landau IME, Laurell C-G. Ultrasound biomicroscopy examination of intraocular lens haptic position after phacoemulsification with continuous curvilinear capsulorhexis and extracapsular cataract extraction with linear capsulotomy[J]. Acta Ophthalmol Scand,1999,77(4):394-396.
[6]
Barbero S,Marcos S,Montejo J, et al. Design of isoplanatic aspheric monofocal intraocular lenses[J]. Opt Express,2011,19(7):6215-6230.
[7]
Holladay JT, Piers PA, Koranyi G, et al. A new intraocular lens design to reduce spherical aberration of pseudophakic eye[J]. J Refract Surg,2002,18(6):683-691.
[8]
Liou HL, Brennan NA. Anatomically accurate, finite model eye for optical modeling[J]. J Opt Soc Am A Opt Image Sci Vis,1997,14(8):1684-1695.
[9]
Findl O, Drexler W, Menapace R, et al. Changes in intraocular lens position after neodymium: YAG capsulotomy[J]. J Cataract Refract Surg,1999,25(5):659-662.
[10]
Zhao H, Mainster MA. The effect of chromatic dispersion on pseudophakic optical performance[J]. Br J Ophthalmol,2007,91(9):1225-1229.
[11]
ZEMAX Development Corporation. Optical Design Program User′s Guide[Z]. San Diego: ZEMAX Development Corporation,2004.
[12]
Escudero-Sanz I, Navarro R. Off-axis aberrations of a wide-angle schematic eye model[J]. J Opt Soc Am A Opt Image Sci Vis,1999,16(8):1881-1891.
[13]
Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling axis shift[J]. J Cataract Refract Surg,1994,20(5):523-526.
[14]
Buckhurst PJ, Wolffsohn JS, Davies LN, et al. Surgical correction of astigmatism during cataract surgery[J]. Clin Exp Optom,2010, 93(6):409-418.
[15]
Ahmed II, Rocha G, Slomovic AR, et al. Visual function and patient experience after bilateral implantation of toric intraocular lenses[J]. J Cataract Refract Surg,2010,36(4):609-616.
[16]
Kim MH, Chung TY, Chung ES. Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery[J]. Korean J Ophthalmol,2010,24(4):207-212.
[17]
Marcos S, Burns SA, Moreno-Barriusop E, et al. A new approach to the study of ocular chromatic aberrations[J]. Vision Res,1999,39(26):4309-4323.
[18]
Atchison DA, Woods RL, Bradley A. Predicting the effects of optical defocus on human contrast sensitivity[J]. J Opt Soc Am A Opt Image Sci Vis,1998,15(9):2536-2544.
Howarth PA, Zhang XX, Bradley A, et al. Does the chromatic aberration of the eye vary with age[J]. J Opt Soc Am A,1988, 5(12):2087-2092.
[21]
Howarth PA, Bradley A. The longitudinal chromatic aberration of the human eye, and its correction[J]. Vision Res,1986,26(2):361-366.
[22]
Siedlecki D, Ginis H. On the longitudinal chromatic aberration of the intraocular lenses[J]. Optom Vis Sci,2007,84(10):984-989.
[23]
Goda K, Mahjoubfar A, Wang C, et al. Hybrid dispersion laser scanner[J]. Sci Rep,2012,2:445.
[24]
Navarro R, Santamaría J, Bescós J. Accommodation-dependent model of the human eye with aspherics[J]. J Opt Soc Am A,1985,2(8):1273-1281.
[25]
张以谟. 应用光学[M]. 北京:机械工业出版社,1996:345-347.
[26]
Thibos LN, Ye M, Zhang XX, et al. The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans[J]. Appl Opt,1992,31(19):3594-3600.
[27]
Inoue M, Noda T, Ohnuma K, et al. Quality of image of grating target placed in model eye and observed through toric intraocular lenses[J]. Am J Ophthalmol,2013,155(2):243-252.