Objective: To study the efficacy, safety, and change in visual quality of a phakic posterior chamber implantable collamer lens with centra FLOW (PPC-ICL V4c) for correcting high myopia. Methods: This was a prospective study of 58 eyes of 32 patients who were candidates for PPC-ICL V4c. The following indicators were compared: preoperative and postoperative uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), preoperative aberrations and aberrations 6 months postoperatively, contrast sensitivity, and the Quality of Life Impact of Refractive Correction (QIRC). All patients were followed up for more than 6 months. Data were analyzed using paired t-tests. Results: Preoperative UCVA (LogMAR visual acuity) and UCVA 6 months after surgery was 1.54±0.26 and -0.04±0.06, respectively. Visual acuity 6 months after surgery improved compared to preoperative acuity (t=30.94, P<0.001). Compared to preoperative BCVA, 56 eyes had equal or better BCVA 6 months after surgery, which accounted for 97% of the total number of eyes. There was an increase of 1 row or better for 28 eyes, which accounted for 48% of the total number of eyes. Postoperative higher-order wavefront aberrations, spherical aberrations, coma, and trefoil root mean square (RMS) were 0.292±0.093 μm, -0.030±0.050 μm, 0.096±0.090 μm,and 0.224±0.091 μm, respectively. Total higher-order aberrations increased and coma was reduced, but the differences were not statistically significant. Spherical aberrations were reduced (t=3.87, P=0.001) and trefoil increased (t=-5.47, P<0.001). All contrast sensitivities 6 months after surgery were better than preoperative levels for 3.0, 6.0, 12.0, and 18.0 cycles/degree. There were also significant differences between the photopic 3.0 and 6.0 cycles/degree and mesopic 6 cycles/degree (t=-2.12, P=0.047; t=-2.51,P=0.021; t=-3.27, P=0.004). The QIRC score for patients improved (t=-2.41, P=0.039) after surgery.Conclusions: Implants of PPC-ICL V4c are a safe and effective surgical method for correcting high myopia. All patients are satisfied with the surgery, which can improve visual quality and quality of life.
王红霞,周奇志,高阳. 有晶状体眼后房型人工晶状体V4c植入术矫正高度近视的临床效果[J]. 中华眼视光学与视觉科学杂志, 2017, 19(8): 476-481.
Hongxia Wang,Qizhi Zhou,Yang Gao. Clinical Effects of a Phakic Posterior Chamber Implantable Collamer Lenswith Centra FLOW for Correcting High Myopia. Chinese Journal of Optometry Ophthalmology and Visual science, 2017, 19(8): 476-481.
Huseynova T, Ozaki S, Ishizuka T, et al. Comparative study of 2 types of implantable collamer lenses, 1 with and 1 without a central artificial hole. Am J Ophthalmol, 2014, 157(6): 1136-1143.DOI: 10.1016/j.ajo.2014.01.032.
[5]
Kamiya K, Shimizu K, Ando W, et al. Comparison of vault after implantation of posterior chamber phakic intraocular lens with
and without a central hole. J Cataract Refract Surg, 2015, 41(1):67-72. DOI: 10.1016/j.jcrs.2014.11.011.
Pesudovs K, Garamendi E, Elliott DB. The Quality of Life Impact of Refractive Correction (QIRC) Questionnaire: development and validation. Optom Vis Sci, 2004, 81(10): 769-777.
Higueras-Esteban A, Ortiz-Gomariz A, Gutiérrez-Ortega R, et al.Intraocular pressure after implantation of the Visian Implantable Collamer Lens with Centra FLOW without iridotomy. Am J Ophthalmol, 2013, 156(4): 800-805. DOI: 10.1016/j.ajo.
20
13.05.018.[11] Kamiya K, Shimizu K, Igarashi A, et al. Clinical evaluation of optical quality and intraocular scattering after posterior chamber phakic intraocular lens implantation. Invest Ophthalmol Vis Sci,2012, 53(6): 3161-3166. DOI: 10.1167/iovs.12-9650.
[12]
Alfonso JF, Lisa C, Fernández-Vega CL, et al. Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.J Cataract Refract Surg, 2013, 39(6): 915-921. DOI: 10.1016/j.jcrs.2013.01.036.
[13]
王雁, 赵堪兴. 波前像差与临床视觉矫正. 北京: 人民卫生出版社, 2011: 34.
[14]
Toto L, Vecchiarino L, D'Ugo E, et al. Astigmatism correction with toric IOL: analysis of visual performance, position,and wavefront error. J Refract Surg, 2013, 29(7): 476-483. DOI:10.3928/1081597X-20130617-06.
Pesudovs K, Garamendi E, Keeves JP, et al. The activities of Daily Vision Scale for cataract surgery outcomes: re-evaluating validity with Rasch analysis. Invest Ophthalmol Vis Sci, 2003,44(7): 2892-2899.
Pérez-Vives C, Ferrer-Blasco T, Madrid-Costa D, et al. Optical quality comparison of conventional and hole-visian implantable collamer lens at different degrees of decentering. Am J Ophthalmol,2013, 156(1): 69-76. e1. DOI: 10.1016/j.ajo.2013.01.030.
[19]
Shimizu K, Kamiya K, Igarashi A, et al. Intraindividual comparison of visual performance after posterior chamber phakic intraocular lens with and without a central hole implantation for moderate to high myopia. Am J Ophthalmol, 2012, 154(3): 486-494.e1. DOI: 10.1016/j.ajo.2012.04.001.